Effects of equipment dead space and pediatric breathing patterns on inhaled mass of nebulized budesonide.

作者信息

Nikander K, Denyer J, Smaldone G C

机构信息

Astra Draco AB, Lund, Sweden.

出版信息

J Aerosol Med. 1999 Summer;12(2):67-73. doi: 10.1089/jam.1999.12.67.

DOI:10.1089/jam.1999.12.67
PMID:10539709
Abstract

Inhaled mass, the quantity of aerosolized drug actually inhaled by a patient, can be estimated in vitro by using a piston pump and an inhaled mass filter in a manner that simulates in vivo aerosol delivery. For pediatric patients, measurement with an inhaled mass filter with a large equipment dead space (VDEQ) in relation to a small tidal volume (VT) may underestimate the inhaled mass. The present study investigated the impact of VDEQ on the accuracy of in vitro measured inhaled mass of budesonide suspension for nebulization using Spira Module 1 jet nebulizers (Respiratory Care Center, Hämeenlinna, Finland), inhaled mass filters, VDEQs of different sizes, and pediatric breathing patterns. The VDEQ varied between 14 and 108 mL, and the breathing patterns corresponded to a VT between 50 and 500 mL, to breathing frequencies of 40 to 12 per min-1, to a duty cycle of 0.5 for all breathing patterns, and to a nebulization time of 2 minutes. The results showed that the inhaled mass was a function of the VDEQ for each breathing pattern as defined by the inspiratory minute volume (VI). For a large VT, a small VDEQ affected the inhaled mass of budesonide only marginally, but as the VDEQ increased, the measured inhaled mass decreased to the point that for a VDEQ larger than the VT, the inhaled mass was zero. When the inhaled mass was expressed as a function of an effective volume (VEFF) (i.e., VI corrected for VDEQ), the results showed a linear correlation (R2 = 0.921) between the volume of aerosol inhaled through the nebulizer and the inhaled mass of budesonide. The results of the study indicate that VDEQ has a critical effect on the measurement of inhaled mass in vitro for conventional jet nebulizers using pediatric breathing patterns. This means that the in vitro measured inhaled mass of drug can seriously underestimate the in vivo value. When pediatric breathing patterns are used in vitro, a correction of the VT by the VDEQ should be made in order to more accurately reflect the in vivo inhaled mass of drug.

摘要

相似文献

1
Effects of equipment dead space and pediatric breathing patterns on inhaled mass of nebulized budesonide.
J Aerosol Med. 1999 Summer;12(2):67-73. doi: 10.1089/jam.1999.12.67.
2
Validation of a new breathing simulator generating and measuring inhaled aerosol with adult breathing patterns.
J Aerosol Med. 2000 Summer;13(2):139-46. doi: 10.1089/089426800418668.
3
The conventional ultrasonic nebulizer proved inefficient in nebulizing a suspension.传统的超声雾化器在雾化悬浮液方面效率低下。
J Aerosol Med. 1999 Summer;12(2):47-53. doi: 10.1089/jam.1999.12.47.
4
Variation in pediatric aerosol delivery: importance of facemask.儿科气雾剂给药的差异:面罩的重要性。
J Aerosol Med. 2005 Fall;18(3):354-63. doi: 10.1089/jam.2005.18.354.
5
In vitro delivery of budesonide from 30 jet nebulizer/compressor combinations using infant and child breathing patterns.采用婴幼儿呼吸模式,从 30 个射流雾化器/压缩机组合中体外输送布地奈德。
Respir Care. 2009 Dec;54(12):1671-8.
6
Impact of constant and breath-synchronized nebulization on inhaled mass of nebulized budesonide in infants and children.持续雾化与呼吸同步雾化对婴幼儿雾化吸入布地奈德吸入量的影响。
Pediatr Pulmonol. 1999 Sep;28(3):187-93. doi: 10.1002/(sici)1099-0496(199909)28:3<187::aid-ppul5>3.0.co;2-j.
7
Effect of mask dead space and occlusion of mask holes on delivery of nebulized albuterol.面罩死腔及面罩孔堵塞对雾化吸入沙丁胺醇给药的影响。
Respir Care. 2014 Aug;59(8):1228-32. doi: 10.4187/respcare.02978.
8
Aerosol delivery during spontaneous breathing with different types of nebulizers- in vitro/ex vivo models evaluation.不同类型雾化器在自主呼吸时的气溶胶输送 - 体外/离体模型评估。
Pulm Pharmacol Ther. 2018 Feb;48:225-231. doi: 10.1016/j.pupt.2017.12.006. Epub 2017 Dec 19.
9
Facial and ocular deposition of nebulized budesonide: effects of face mask design.雾化布地奈德在面部和眼部的沉积:面罩设计的影响
Chest. 2008 Feb;133(2):482-8. doi: 10.1378/chest.07-1827. Epub 2007 Dec 10.
10
Effects of flow pattern, device and formulation on particle size distribution of nebulized aerosol.雾化气溶胶的流型、装置和配方对粒径分布的影响。
Int J Pharm. 2019 Apr 5;560:35-46. doi: 10.1016/j.ijpharm.2019.01.025. Epub 2019 Jan 19.

引用本文的文献

1
Compatible Stability and Aerosol Characteristics of Atrovent (Ipratropium Bromide) Mixed with Salbutamol Sulfate, Terbutaline Sulfate, Budesonide, and Acetylcysteine.爱全乐(异丙托溴铵)与硫酸沙丁胺醇、硫酸特布他林、布地奈德及乙酰半胱氨酸混合后的配伍稳定性和气雾剂特性
Pharmaceutics. 2020 Aug 15;12(8):776. doi: 10.3390/pharmaceutics12080776.