Pipe J G
Department of Radiology, Wayne State University, Detroit, Michigan, USA.
Magn Reson Med. 1999 Nov;42(5):963-9. doi: 10.1002/(sici)1522-2594(199911)42:5<963::aid-mrm17>3.0.co;2-l.
A method for motion correction, involving both data collection and reconstruction, is presented. The PROPELLER MRI method collects data in concentric rectangular strips rotated about the k-space origin. The central region of k-space is sampled for every strip, which (a) allows one to correct spatial inconsistencies in position, rotation, and phase between strips, (b) allows one to reject data based on a correlation measure indicating through-plane motion, and (c) further decreases motion artifacts through an averaging effect for low spatial frequencies. Results are shown in which PROPELLER MRI is used to correct for bulk motion in head images and respiratory motion in nongated cardiac images. Magn Reson Med 42:963-969, 1999.
本文提出了一种涉及数据采集和重建的运动校正方法。螺旋桨磁共振成像(PROPELLER MRI)方法在围绕k空间原点旋转的同心矩形条带中采集数据。对每个条带的k空间中心区域进行采样,这使得:(a)能够校正条带之间在位置、旋转和相位上的空间不一致性;(b)能够基于表示层面内运动的相关度量来剔除数据;(c)通过对低空间频率的平均效应进一步减少运动伪影。展示了使用螺旋桨磁共振成像校正头部图像中的整体运动和非门控心脏图像中的呼吸运动的结果。《磁共振医学》42:963 - 969, 1999年。