Suppr超能文献

使用单换能器脉冲波超声系统测量造影剂的固有和自然谐波响应。

Measurement of the contrast agent intrinsic and native harmonic response with single transducer pulse waved ultrasound systems.

作者信息

Verbeek X A, Willigers J M, Brands P J, Ledoux L A, Hoeks A P

机构信息

Department of Biophysics, Cardiovascular Research Institute Maastricht, Maastricht University, The Netherlands.

出版信息

Ann Biomed Eng. 1999 Sep-Oct;27(5):670-81. doi: 10.1114/1.209.

Abstract

Ultrasound contrast agents, i.e., small gas filled microbubbles, enhance the echogenicity of blood and have the potential to be used for tissue perfusion assessment. The contrast agents scatter ultrasound in a nonlinear manner and thereby introduce harmonics in the ultrasound signal. This property is exploited in new ultrasound techniques like harmonic imaging, which aims to display only the contrast agent presence. Much attention has already been given to the physical properties of the contrast agent. The present study focuses on practical aspects of the measurement of the intrinsic harmonic response of ultrasound contrast agents with single transducer pulse waved ultrasound systems. Furthermore, the consequences of two other sources of harmonics are discussed. These sources are the nonlinear distortion of ultrasound in a medium generating native harmonics, and the emitted signal itself which might contain contaminating harmonics. It is demonstrated conceptually and by experiments that optimization of the contrast agent harmonic response measured with a single transducer is governed by the transducer spectral sensitivity distribution rather than the resonance properties of the contrast agent. Both native and contaminating harmonics may be of considerable strength and can be misinterpreted as intrinsic harmonics of the contrast agent. Practical difficulties to filter out the harmonic component selectively, without deteriorating the image, may cause misinterpretation of the fundamental as a harmonic.

摘要

超声造影剂,即充满气体的微小气泡,可增强血液的回声性,并有可能用于组织灌注评估。造影剂以非线性方式散射超声,从而在超声信号中引入谐波。这种特性被用于谐波成像等新的超声技术中,其目的是仅显示造影剂的存在。人们已经对造影剂的物理特性给予了很多关注。本研究聚焦于使用单换能器脉冲波超声系统测量超声造影剂固有谐波响应的实际问题。此外,还讨论了另外两种谐波来源的影响。这两种来源分别是介质中超声产生固有谐波的非线性失真,以及发射信号本身可能包含的干扰谐波。通过概念演示和实验表明,用单换能器测量造影剂谐波响应的优化取决于换能器的频谱灵敏度分布,而非造影剂的共振特性。固有谐波和干扰谐波的强度都可能相当大,并且可能被误判为造影剂的固有谐波。在不降低图像质量的情况下选择性滤除谐波成分的实际困难,可能会导致将基波误判为谐波。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验