Suppr超能文献

高结晶度MP-1羟基磷灰石涂层。第二部分:在犬类骨内牙根种植体上的体内性能。

Highly crystalline MP-1 hydroxylapatite coating. Part II: In vivo performance on endosseous root implants in dogs.

作者信息

Burgess A V, Story B J, Wagner W R, Trisi P, Pikos M A, Guttenberg S A

机构信息

SULZERMEDICA, Sulzer Calcitek Inc., Carlsbad, California 92008, USA.

出版信息

Clin Oral Implants Res. 1999 Aug;10(4):257-66. doi: 10.1034/j.1600-0501.1999.100402.x.

Abstract

The in vivo integration strength and degree of bone apposition were compared for oral endosseous implants with different plasma-sprayed hydroxylapatite (HA) coatings. Pullout strength measurements and histological analysis were used to compare two different commercially available coating from the same manufacturer. One coating does not receive a post-plasma-spray treatment and contains about 75% crystalline HA. The other coating is treated with the MP-1 process, a pressurized hydrothermal post-plasma-spray process, which increases the coating composition to approximately 95% crystalline HA without changing the coating's adhesive or cohesive strength. Comparisons were made in dogs after healing times of 3 and 15 weeks in the mandible. No significant differences were found in either case between the two coatings. Two different methods were used to determine the degree of bone apposition at 15 weeks. Both methods confirmed that the MP-1 process does not affect the osseointegration rate of plasma-sprayed HA coatings. Qualitative histology data suggest that the treated coating is more stable than the control coating, especially in cases of direct soft tissue attachment to the implant. The present data suggest that extensive dissolution of calcium phosphate components into surrounding tissue is not a necessary precursor for direct apposition of bone to HA-coated implants.

摘要

对具有不同等离子喷涂羟基磷灰石(HA)涂层的口腔骨内植入物的体内整合强度和骨附着程度进行了比较。采用拔出强度测量和组织学分析来比较同一制造商生产的两种不同的市售涂层。一种涂层未经过等离子喷涂后处理,含有约75%的结晶HA。另一种涂层采用MP - 1工艺处理,即一种加压水热等离子喷涂后处理工艺,该工艺在不改变涂层粘结或内聚强度的情况下,将涂层成分提高到约95%的结晶HA。在下颌骨愈合3周和15周后,在犬类动物身上进行了比较。在这两种情况下,两种涂层之间均未发现显著差异。使用两种不同方法来确定15周时的骨附着程度。两种方法均证实MP - 1工艺不会影响等离子喷涂HA涂层的骨整合率。定性组织学数据表明,经过处理的涂层比对照涂层更稳定,尤其是在软组织直接附着于植入物的情况下。目前的数据表明,磷酸钙成分大量溶解到周围组织中并非骨直接附着于HA涂层植入物的必要前提。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验