Yong S C, Smith C M, Wach R, Kurian M, Primhak R A
University Dept of Paediatrics, Children's Hospital, Sheffield, UK.
Eur Respir J. 1999 Nov;14(5):1175-8. doi: 10.1183/09031936.99.14511759.
Tracheal/chest auscultation for wheeze and transcutaneous oximetry have both been suggested as measures of outcome in bronchial provocation tests in young children. This study aimed to compare the sensitivity and safety of these two techniques as end-points for methacholine challenge in children aged <4 yrs. Seventy-two methacholine challenges were performed in 39 children aged <4 yrs with recurrent wheeze. Arterial oxygen saturation (Sa,O2) and transcutaneous oxygen pressure tcPO2 continuously, and the test was terminated when wheeze was heard or at Sa,O2 <91%. tcPO2 was not used as an end-point. Wheeze or desaturation occurred at < or =8 mg x mL(-1) methacholine in every test. One child had transient clinical cyanosis, but no other ill-effects were seen. Fifty-six tests (78%) were terminated for wheeze, seven (10%) for fall in Sa,O2 and nine (12%) showed simultaneous responses in both parameters. Twenty-eight tests (39%) contained a fall in tcPO2 >3 kPa but six of these also showed a significant rise. Fifty-three tests (75%) contained a fall in tcPO2 >15%, but 20 of these also showed a significant rise. Tracheal/chest auscultation with Sa,O2 monitoring is a sensitive and relatively safe end-point for bronchial challenges in preschool children. The erratic pattern of transcutaneous oxygen pressure response in some children casts doubt on its reliability as a proxy measure of bronchial obstruction.
气管/胸部听诊判断哮鸣音以及经皮血氧饱和度测定,都被认为是幼儿支气管激发试验的结果衡量指标。本研究旨在比较这两种技术作为4岁以下儿童乙酰甲胆碱激发试验终点的敏感性和安全性。对39名4岁以下复发性喘息儿童进行了72次乙酰甲胆碱激发试验。连续监测动脉血氧饱和度(Sa,O2)和经皮氧分压tcPO2,当听到哮鸣音或Sa,O2<91%时终止试验。tcPO2未用作终点指标。每次试验中,在乙酰甲胆碱浓度≤8mg x mL(-1)时均出现哮鸣音或血氧饱和度下降。1名儿童出现短暂的临床发绀,但未见其他不良反应。56次试验(78%)因哮鸣音而终止,7次(10%)因Sa,O2下降而终止,9次(12%)在两个参数上同时出现反应。28次试验(39%)的tcPO2下降>3kPa,但其中6次也出现了显著上升。53次试验(75%)的tcPO2下降>15%,但其中20次也出现了显著上升。气管/胸部听诊联合Sa,O2监测是学龄前儿童支气管激发试验敏感且相对安全的终点指标。部分儿童经皮氧分压反应的不稳定模式使其作为支气管阻塞替代指标的可靠性存疑。