Sturesson B, Uden A, Vleeming A
Department of Orthopaedics NVS Angelholm, Sweden.
Spine (Phila Pa 1976). 2000 Jan 15;25(2):214-7. doi: 10.1097/00007632-200001150-00012.
A Radiostereometric analysis of the reciprocal straddle position.
To evaluate the magnitude of rotation in the sacroiliac joints in the reciprocal straddle position.
The reciprocal straddle position has been objectified in different studies, using different techniques, to show a sacroiliac motion between 5 degrees and 36 degrees. Previous studies with radiostereometric analysis during different provocations reported much smaller movements.
Six women with posterior pelvic pain of long duration after pregnancy (n = 5) and sacroiliitis (n = 1) underwent radiostereometric analysis in the sustained reciprocal straddle position.
A reciprocal movement could be demonstrated in the sacroiliac joints in the reciprocal straddle position. However, the movements were 10 times smaller than reported in earlier studies of the reciprocal straddle position.
It was possible to demonstrate reciprocal movements of the sacroiliac joints in the straddle position. However, the radiostereometric analysis technique showed the movements to be small, as reported in other mobility studies.
对相对跨坐姿势进行放射立体测量分析。
评估相对跨坐姿势下骶髂关节的旋转幅度。
在不同研究中,采用不同技术对相对跨坐姿势进行了客观化研究,结果显示骶髂关节运动范围在5度至36度之间。先前在不同激发试验期间进行放射立体测量分析的研究报告的运动幅度要小得多。
对6名产后长期存在骨盆后部疼痛的女性(5例为产后疼痛,1例为骶髂关节炎)在持续相对跨坐姿势下进行放射立体测量分析。
在相对跨坐姿势下,骶髂关节可表现出相对运动。然而,这些运动比早期相对跨坐姿势研究报告的运动小10倍。
在跨坐姿势下能够证明骶髂关节存在相对运动。然而,正如其他活动度研究报告的那样,放射立体测量分析技术显示这些运动幅度较小。