Abstract

Three small-size (nominal size: 19 mm) bileaflet valves, CarboMedics R (CM), St Jude Standard (SJ) and Sorin Bicarbon (SB), have been tested by means of a two-component laser Doppler anemometry (LDA) system, in the mitral position, in order to assess the potential damage to blood elements entailed by the turbulent flow through them. A high regime (6 l/min cardiac output) was chosen to perform measurements for the worst case in generated turbulence. Two half-diameter profiles, at 13 and 26 mm downstream of the valve plane, have been investigated for each model. Besides velocity profiles, turbulence shear stresses (TSS) are reported, after the application of the stress analysis technique, in order to assess the maximum values of TSS (TSSmax) exerted on blood particles. Results show the typical bileaflet-type velocity profile for SB and SJ, with three jets exiting the valve, whereas CM lacks the central jet, due to instabilities of its flow field. As for TSSmax, CM reaches the highest values, presumably due to leaflets fluttering. SJ's TSSmax profiles maintain similar shapes at the two downstream locations, whereas SB presents an unexpected increase in the peak value of TSSmax, from 13 to 26 mm downstream of the valve plane, probably due to the curved leaflet design. The three prosthetic heart valves (PHVs) tested show many differences as for their turbulence properties, although they are similarly constructed.

摘要

采用双分量激光多普勒测速(LDA)系统,对三个小尺寸(标称尺寸:19毫米)的双叶瓣瓣膜,即CarboMedics R(CM)、圣犹达标准型(SJ)和索林碳酸氢盐型(SB),在二尖瓣位置进行了测试,以评估血液成分因流经这些瓣膜产生的湍流而可能受到的损伤。选择高流量状态(心输出量为6升/分钟)进行测量,以模拟产生湍流的最坏情况。对每个型号的瓣膜,研究了瓣膜平面下游13毫米和26毫米处的两个半直径剖面。除了速度剖面外,在应用应力分析技术后,还报告了湍流剪应力(TSS),以评估作用于血液颗粒上的最大剪应力值(TSSmax)。结果显示,SB和SJ呈现典型的双叶瓣型速度剖面,有三股射流从瓣膜流出,而CM由于其流场不稳定,缺少中央射流。至于TSSmax,CM达到最高值,可能是由于瓣叶颤动。SJ的TSSmax剖面在两个下游位置保持相似的形状,而SB在瓣膜平面下游13毫米至26毫米处,TSSmax峰值意外增加,这可能是由于瓣叶的弯曲设计。所测试的三种人工心脏瓣膜(PHV),尽管结构相似,但在湍流特性方面存在许多差异。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验