Hempe J M, Craver R D
Department of Pediatrics, Louisiana State University School of Medicine, New Orleans 70112, USA.
Electrophoresis. 2000 Mar;21(4):743-8. doi: 10.1002/(SICI)1522-2683(20000301)21:4<743::AID-ELPS743>3.0.CO;2-1.
Clinical assays for the primary evaluation of congenital hemoglobin (Hb) disorders must detect and identify a variety of Hb variants. We analyzed hemolysates containing Hb variants with similar charge to evaluate the diagnostic sensitivity and specificity of automated capillary isoelectric focusing (CIEF). Peak separation was observed for each variant in samples containing Hb S, D, and G. The calculated isoelectric points (pI) of these variants were significantly different such that each could be identified in a single run with pI as the sole criterion of identification. The pI of Hb C was significantly different from that of Hb E, C-Harlem, and O-Arab. Hb E, C-Harlem, and O-Arab had similar pI and were not readily differentiated. Hb Koln, M-Saskatoon, Aida, and S/Aida hybrid were readily separated from common Hb variants and detected by CIEF. We conclude that CIEF exhibits both diagnostic sensitivity and specificity, and that pI is an objective and specific criterion of Hb variant identification.
用于先天性血红蛋白(Hb)疾病初步评估的临床检测必须能够检测和识别多种Hb变体。我们分析了含有电荷相似的Hb变体的溶血产物,以评估自动毛细管等电聚焦(CIEF)的诊断敏感性和特异性。在含有Hb S、D和G的样品中观察到了每个变体的峰分离。这些变体的计算等电点(pI)有显著差异,因此每个变体都可以在单次运行中以pI作为唯一的识别标准进行识别。Hb C的pI与Hb E、C-哈勒姆和O-阿拉伯的pI有显著差异。Hb E、C-哈勒姆和O-阿拉伯具有相似的pI,不容易区分。Hb科隆、M-萨斯卡通、阿依达和S/阿依达杂交体很容易与常见的Hb变体分离,并通过CIEF检测到。我们得出结论,CIEF具有诊断敏感性和特异性,并且pI是Hb变体识别的客观和特异性标准。