Suppr超能文献

温度对氯乙烯单体采样过程中活性炭管穿透的影响。

Effect of temperature on the breakthrough of a charcoal tube during vinyl chloride monomer sampling.

作者信息

Roh J, Park Y J, Kim C N, Lim N G, Lee S H, Song J S, Won J U, Talaska G

机构信息

Institute for Occupational Health, Yonsei University College of Medicine, Seoul, Korea.

出版信息

AIHAJ. 2000 May-Jun;61(3):405-9. doi: 10.1080/15298660008984551.

Abstract

This study evaluated the effects of temperature on breakthrough of two standard collection media at various concentrations during vinyl chloride monomer (VCM) sampling. The National Institute for Occupational Safety and Health (NIOSH) and Occupational Safety and Health Administration (OSHA) methods were evaluated. To determine whether breakthrough of VCM would occur at the extremes of exposure and temperature that might be encountered in some workplaces, air samples containing 4 ppm (10.24 mg/m3), 8 ppm (20.45 mg/m3), 16 ppm (40.98 mg/m3), and 32 ppm (81.80 mg/m3) of VCM were collected at temperatures of 4, 22, and 40 degrees C. Five liters of air was sampled at the rate of 0.05 L/min for 100 min using the activated charcoal tube recommended by NIOSH. A second tube was added to the sampling train to collect any VCM that might not have been absorbed in the first tube. To collect VCM air samples by the OSHA method, two carbon molecular sieve tubes were connected serially and 3 L of air was sampled at the rate of 0.05 L/min for 60 min. A gas chromatograph with a flame ionization detector and ultra 2 capillary column was used to analyze VCM. Significant breakthrough was found when sampling at higher temperatures with the NIOSH method. No breakthrough was found when samples were collected using the OSHA media at different temperatures and concentrations. Therefore, under hot ambient conditions (>22 degrees C), the possibility of breakthrough should be considered when sampling VCM by the NIOSH method.

摘要

本研究评估了温度对氯乙烯单体(VCM)采样过程中两种标准采集介质在不同浓度下穿透情况的影响。对美国国家职业安全与健康研究所(NIOSH)和职业安全与健康管理局(OSHA)的方法进行了评估。为了确定在某些工作场所可能遇到的极端暴露和温度条件下VCM是否会发生穿透,在4、22和40摄氏度的温度下采集了含有4 ppm(10.24 mg/m³)、8 ppm(20.45 mg/m³)、16 ppm(40.98 mg/m³)和32 ppm(81.80 mg/m³)VCM的空气样本。使用NIOSH推荐的活性炭管,以0.05 L/min的流速采集5升空气,采样时间为100分钟。在采样系列中添加第二根管子,以收集可能未被第一根管子吸收的任何VCM。为了通过OSHA方法采集VCM空气样本,将两根碳分子筛管串联连接,以0.05 L/min的流速采集3升空气,采样时间为60分钟。使用配备火焰离子化检测器和Ultra 2毛细管柱的气相色谱仪分析VCM。发现使用NIOSH方法在较高温度下采样时存在显著穿透。当使用OSHA介质在不同温度和浓度下采集样本时,未发现穿透。因此,在炎热的环境条件下(>22摄氏度),使用NIOSH方法采样VCM时应考虑穿透的可能性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验