Ruhswurm I, Scholz U, Zehetmayer M, Hanselmayer G, Vass C, Skorpik C
Department of Ophthalmology, University of Vienna Medical School, Austria.
J Cataract Refract Surg. 2000 Jul;26(7):1022-7. doi: 10.1016/s0886-3350(00)00317-5.
To determine the efficacy and rotational stability of a toric posterior chamber silicone intraocular lens (IOL) to correct preoperative astigmatism in cataract patients.
Department of Ophthalmology, University Hospital of Vienna, Vienna Austria.
Between 1993 and 1998, foldable toric single-piece plate-haptic silicone IOLs were implanted in 37 eyes (30 patients). The cylindrical IOL power was 2.00 diopters (D) (n = 29), 3.50 D (n = 7), or 4.00 D (n = 1). Phacoemulsification was performed through a scleral or a corneal sutureless self-sealing incision. Outcomes of Snellen visual acuity (without, with spherical, and with best correction), refractive and keratometric astigmatism, and IOL rotation after early postoperative (mean 15.9 days +/- 10.1 [SD]) and long-term (mean 20.3 +/- 16.6 months) follow-ups were evaluated.
At last follow-up, 31 eyes (83.8%) had a spherically corrected and 34 (91.9%) a best corrected visual acuity of 0.5 (20/40) or better. Mean preoperative refractive and keratometric astigmatism was 2.68 and 2.70 D, respectively. At the last postoperative follow-up, mean refractive astigmatism was reduced to 0.84 D; keratometric astigmatism was 2.30 D. In 7 eyes (18.9%), the IOL axis was rotated a maximum of 25 degrees. In all 37 eyes, the axis of the toric IOL remained within 30 degrees of rotation.
Early postoperative and long-term follow-ups showed effective and stable correction of astigmatism after implantation of a foldable toric posterior chamber silicone IOL.
确定有晶状体后房型硅酮人工晶状体(IOL)矫正白内障患者术前散光的疗效和旋转稳定性。
奥地利维也纳大学医院眼科。
1993年至1998年期间,将可折叠的单一片状板襻硅酮IOL植入37只眼(30例患者)。柱镜IOL度数为2.00屈光度(D)(n = 29)、3.50 D(n = 7)或4.00 D(n = 1)。通过巩膜或角膜无缝线自闭式切口进行超声乳化。评估术后早期(平均15.9天±10.1[标准差])和长期(平均20.3±16.6个月)随访后的Snellen视力(未矫正、球面矫正和最佳矫正)、屈光性和角膜散光以及IOL旋转情况。
在最后一次随访时,31只眼(83.8%)的球面矫正视力和34只眼(91.9%)的最佳矫正视力达到0.5(20/40)或更好。术前平均屈光性和角膜散光分别为2.68 D和2.70 D。在最后一次术后随访时,平均屈光性散光降至0.84 D;角膜散光为2.30 D。7只眼(18.9%)的IOL轴最多旋转了25度。在所有37只眼中,有晶状体IOL的轴旋转均未超过30度。
术后早期和长期随访显示,植入可折叠的有晶状体后房型硅酮IOL后,散光矫正有效且稳定。