Suppr超能文献

Derivation of [(11)C]WAY-100635 binding parameters with reference tissue models: effect of violations of model assumptions.

作者信息

Slifstein M, Parsey R V, Laruelle M

机构信息

Department of Psychiatry, Columbia University College of Physicians and Surgeons, New York, New York, USA.

出版信息

Nucl Med Biol. 2000 Jul;27(5):487-92. doi: 10.1016/s0969-8051(00)00117-7.

Abstract

In several positron-emission tomography studies of human subjects, analyses of data from the 5-hydroxytryptamine(1A) (5-HT(1A)) receptor radioligand, [(11)C]WAY-100635 ¿[carbonyl-(11)C]N-(2-(4-methoxy-phenyl)-1-piperazin-1-yl)ethyl)-N -(2 -pyridyl)cyclohexanecarboxamide¿ have shown a discrepancy between the outcome measure k(3)/k(4) (binding potential normalized to cerebellum) as estimated by the simplified reference region method and results obtained by conventional kinetic modeling with an arterial input function. The reference region method has yielded results that are lower than the conventional approach, with the relative underestimation appearing to be an increasing function of k(3)/k(4). We performed simulations on idealized data to identify the source of the discrepancy. Both the simplified reference tissue model (SRTM) and the original full reference tissue model (FRTM) were tested to determine (a) if the error in estimated k(3)/k(4) is dependent on the blood flow in the region of interest relative to the blood flow in the region of reference (R(1)) and on the receptor density in the region of interest (true k(3)/k(4)), and (b) which violation of the reference model assumptions were responsible for this effect. FRTM returned parameter estimates that were independent and accurate if the reference region was constructed precisely as a one-tissue compartment model. SRTM overestimated k(3)/k(4) when the reference region was constructed as a one-tissue compartment model and underestimated k(3)/k(4) when the reference region was constructed as a two-tissue compartment model (which is the case for [(11)C]WAY-100635). In both cases, the magnitude of the error in k(3)/k(4) returned by SRTM was dependent on true R(1) and true k(3)/k(4). In conclusion, the SRTM is associated with a bias in the derivation of k(3)/k(4) that is not a simple scaling factor. This magnitude of these errors should be carefully evaluated for each new radioligand.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验