Measurement of cardiac output by thermal dilution in infants and children.

作者信息

Wyse S D, Pfitzner J, Rees A, Lincoln J C, Branthwaite M A

出版信息

Thorax. 1975 Jun;30(3):262-5. doi: 10.1136/thx.30.3.262.

Abstract

The accuracy of the thermal dilution technique for measuring cardiac output in infants and children has been assessed by comparison with the direct Fick technique. Satisfactory correlation between the two methods has been demonstrated, and it is concluded that a commercially available monitor can be used to determine cardiac output by thermal dilution in acutely sick infants and children. The volume of injectate should be selected according to the weight of the child, and the value displayed by the monitor should be adjusted by the appropriate fraction.

摘要

相似文献

1
Measurement of cardiac output by thermal dilution in infants and children.
Thorax. 1975 Jun;30(3):262-5. doi: 10.1136/thx.30.3.262.
4
Cardiac output determination in infants and small children after open intracardiac operations.
Ann Thorac Surg. 1975 Mar;19(3):322-6. doi: 10.1016/s0003-4975(10)64026-x.
5
Measurement of cardiac output by thermal dilution.
Am J Cardiol. 1971 Jul;28(1):54-8. doi: 10.1016/0002-9149(71)90034-8.
8
Thermodilution cardiac output measurement in infants and small children following intracardiac surgery.
J Pediatr Surg. 1975 Oct;10(5):649-56. doi: 10.1016/0022-3468(75)90368-1.
10
Validity of thermal dilution technique for measurement of cardiac output in rats.
Am J Physiol. 1993 Sep;265(3 Pt 2):H1007-13. doi: 10.1152/ajpheart.1993.265.3.H1007.

引用本文的文献

本文引用的文献

1
Thermal-dilution technics.
Circ Res. 1962 Mar;10:491-504. doi: 10.1161/01.res.10.3.491.
2
Determination of cardiac output in man by a new method based on thermodilution.
Lancet. 1963 Jun 22;1(7295):1352-4. doi: 10.1016/s0140-6736(63)91928-7.
3
Cardiac output measured by thermal dilution of room temperature injectate.
J Appl Physiol. 1961 Mar;16:271-5. doi: 10.1152/jappl.1961.16.2.271.
4
Thermal dilution curves in the intact animal.
Circ Res. 1959 May;7(3):432-41. doi: 10.1161/01.res.7.3.432.
5
Measurement of cardiac output by thermal dilution in man.
J Appl Physiol. 1968 Mar;24(3):434-8. doi: 10.1152/jappl.1968.24.3.434.
6
The effect of section of the carotid sinus and aortic nerves on the cardiac output of the rabbit.
J Physiol. 1965 Sep;180(2):266-78. doi: 10.1113/jphysiol.1965.sp007702.
8
Simultaneous determinations of cardiac output by thermal dilution, fiberoptic and dye-dilution methods.
Am J Cardiol. 1970 May;25(5):579-87. doi: 10.1016/0002-9149(70)90597-7.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验