• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Improved method for shooting distance determination. Part 2--bullet holes in objects that cannot be processed in the laboratory.

作者信息

Glattstein B, Zeichner A, Vinokurov A, Shoshani E

机构信息

Division of Identification and Forensic Science, Israel National Police Headquarters, Jerusalem.

出版信息

J Forensic Sci. 2000 Sep;45(5):1000-8.

PMID:11005172
Abstract

An improved method for firing distance determination on exhibits that cannot be processed in the laboratory such as cars, doors, windows, or furniture is described. The novel part of the method includes transfer of total nitrite (nitrite ions and smokeless powder residues) from the target to an adhesive lifter. After the transfer, vaporous lead and copper deposits around the bullet entrance hole are visualized on the target by sodium rhodizonate and rubeanic acid, respectively. The Modified Griess Test is carried out after alkaline hydrolysis of the smokeless powder residues on the adhesive lifter.

摘要

相似文献

1
Improved method for shooting distance determination. Part 2--bullet holes in objects that cannot be processed in the laboratory.
J Forensic Sci. 2000 Sep;45(5):1000-8.
2
Improved method for shooting distance estimation. Part 1. Bullet holes in clothing items.
J Forensic Sci. 2000 Jul;45(4):801-6.
3
Improved method for shooting distance estimation. Part III. Bullet holes in cadavers.
J Forensic Sci. 2000 Nov;45(6):1243-9.
4
A novel method for the analysis of discharged smokeless powder residues.一种分析已排出无烟火药残渣的新方法。
J Forensic Sci. 2007 Jan;52(1):75-8. doi: 10.1111/j.1556-4029.2006.00309.x.
5
A preliminary investigation into the use of FTIR microscopy as a probe for the identification of bullet entrance holes and the distance of firing.
Sci Justice. 2009 Sep;49(3):197-204. doi: 10.1016/j.scijus.2008.07.002.
6
Machine washing or brushing of clothing and its influence on shooting distance estimation.衣物的机洗或刷洗及其对射击距离估计的影响。
J Forensic Sci. 2001 Jul;46(4):928-33.
7
A possible source of reference DNA from archived treated adhesive lifters.来自存档处理过的粘性提取器的参考DNA的一个可能来源。
J Forensic Sci. 2004 Jan;49(1):68-70.
8
Determination of firing distance. Lead analysis on the target by atomic absorption spectroscopy (AAS).
J Forensic Sci. 2008 Mar;53(2):321-4. doi: 10.1111/j.1556-4029.2008.00668.x.
9
Analysis of primer residue from lead free ammunition by X-ray microfluorescence.利用X射线微荧光分析法分析无铅弹药中的引物残留。
J Forensic Sci. 2000 Mar;45(2):447-52.
10
The use of unburned propellant powder for shooting-distance determination. Part II: Diphenylamine reaction.未燃烧推进剂粉末在射击距离测定中的应用。第二部分:二苯胺反应。
Forensic Sci Int. 2017 Sep;278:24-31. doi: 10.1016/j.forsciint.2017.06.022. Epub 2017 Jun 27.