Peak contact stress in human hip during gait.

作者信息

Mavcic B, Antolic V, Brand R, Iglic A, Kralj-Iglic V, Pedersen D R

机构信息

Department of Orthopedic Surgery, Clinical Center Ljubljana, Slovenia.

出版信息

Pflugers Arch. 2000;440(5 Suppl):R177-8.

Abstract

The contact stress in a human hip is not uniform and it changes with different body positions. The changing location of the peak contact stress during gait may indicate the predilection sites for further development of osteoarthritis in the hip. On the basis of laboratory measurements and by using mathematical models of forces and stresses in human hip we determined the points of the peak contact stress in successive phases of gait. Results show that the peak stress points are mostly located in the posterior-medial portion of the weight bearing area, which corresponds well to the clinical observations. It is also shown that in the pathological conditions of hip dysplasia the peak contact stress trajectory is located more laterally and anteriorly.

摘要

相似文献

1
Peak contact stress in human hip during gait.
Pflugers Arch. 2000;440(5 Suppl):R177-8.
2
Peak contact stress in human hip during gait.
Pflugers Arch. 2000 Jan;440(Suppl 1):R177-R178. doi: 10.1007/s004240000054.
4
Determination of muscle loading at the hip joint for use in pre-clinical testing.
J Biomech. 2005 May;38(5):1155-63. doi: 10.1016/j.jbiomech.2004.05.022.
5
Acetabular loading in active abduction.
IEEE Trans Neural Syst Rehabil Eng. 2007 Jun;15(2):252-7. doi: 10.1109/TNSRE.2007.897023.
6
Contact stress in hips with osteonecrosis of the femoral head.
Clin Orthop Relat Res. 2006 Jun;447:92-9. doi: 10.1097/01.blo.0000203472.88926.c8.
7
Subject-specific hip geometry affects predicted hip joint contact forces during gait.
J Biomech. 2008;41(6):1243-52. doi: 10.1016/j.jbiomech.2008.01.014. Epub 2008 Mar 17.
8
Effect of 3D physiological loading and motion on elastohydrodynamic lubrication of metal-on-metal total hip replacements.
Med Eng Phys. 2009 Jul;31(6):720-9. doi: 10.1016/j.medengphy.2009.02.002. Epub 2009 Mar 9.
9
Design parameters dependences on contact stress distribution in gait and jogging phases after total hip arthroplasty.
J Biomech. 2008;41(5):1137-42. doi: 10.1016/j.jbiomech.2007.12.009. Epub 2008 Jan 30.
10
Tibiofemoral contact mechanics after serial medial meniscectomies in the human cadaveric knee.
Am J Sports Med. 2006 Aug;34(8):1334-44. doi: 10.1177/0363546506286786. Epub 2006 Apr 24.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验