Suppr超能文献

三叉神经凝固术中孔的简易测定

Simple determination of the foramen in trigeminus coagulation.

作者信息

Martins L F, Umbach W

出版信息

Neurochirurgia (Stuttg). 1975 Sep;18(5):163-6. doi: 10.1055/s-0028-1090446.

Abstract

The object is to achieve a high degree of precision in the determination of the foramen ovale in managing trigeminus neuralgia stereotactically as well as by free-hand penetrations. We carried out exact measurements on lateral skull x-rays of 55 corpses and 25 patients. With the aid of a design and several plain x-ray films we drew connecting-lines between fixed, easily determined points of the skull. The middle of the foramen ovale coincides with the dissecting point of these 3 co-ordinates, the maximal deviation of 2 mm is clinically negligible compared with the total width of the foramen. The average distance of the foramen from the midline as measured on the basic projection is 2.8 cm +/- 2 mm. The puncture technique and the thermocontrolled coagulation of the trigeminus branches are discussed.

摘要

目的是在立体定向以及徒手穿刺治疗三叉神经痛时,在卵圆孔的定位上达到高度精确。我们对55具尸体和25名患者的头颅侧位X线片进行了精确测量。借助一种设计和几张普通X线片,我们在颅骨上固定的、易于确定的点之间绘制了连接线。卵圆孔的中点与这三个坐标的解剖点重合,与卵圆孔的总宽度相比,2毫米的最大偏差在临床上可忽略不计。在基础投影上测量,卵圆孔距中线的平均距离为2.8厘米±2毫米。文中还讨论了穿刺技术以及三叉神经分支的温控凝固。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验