Nasal model and lung model machine for intranasal stent with filters efficacy evaluation.

作者信息

Tanpowpong K

机构信息

Otolaryngology Department, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.

出版信息

J Med Assoc Thai. 2000 Sep;83(9):1077-81.

PMID:11075976
Abstract

Nasal model and lung model machine simulated human respiratory situation with cyclical air flow rate of 2 1/min. They were used to evaluate filtration efficacy of filters in an intranasal stent for laser smoke particles in the Otolaryngology Department, Ramathibodi Hospital from February to June 1998. The filters were three layers of half face mask outer filters. Each of five sets or 10 intranasal stents with filters or Whatman filters was attached at both inlet ends of the nasal model. A Whatman filter collected the maximum particle amount from 10 shots, 10 W and 0.2 s of single pulse mode carbon dioxide laser evaporative field for 5 min which was the same amount passed through filters of the intranasal stent. A high power optical microscope was used to count particle retention in each filter. The mean filtration efficacy of filters in the intranasal stent was 94.4 per cent when compared with that of the Whatman filter. A personal respiratory protective device could be applied in the human nasal vestibule to prevent polydisperse suspended particulate matter in a highly air-polluted area. The nasal model with lung model machine should be tested under different concentrations of laser smoke particles or at the main roadside.

摘要

相似文献

1
Nasal model and lung model machine for intranasal stent with filters efficacy evaluation.
J Med Assoc Thai. 2000 Sep;83(9):1077-81.
2
Efficacy of intranasal stent with filters for different laser smoke particle concentration.
J Med Assoc Thai. 2000 Nov;83(11):1302-6.
3
Personal respiratory protective devices: efficacy of intranasal stent with filters.
J Med Assoc Thai. 2000 Jan;83(1):21-7.
4
Efficacy of the ramathibodi nasal filter in a simulated human airway evaluated by a laser diode portable dust monitor under low laser smoke particle concentration.
J Med Assoc Thai. 2002 Feb;85(2):195-9.
5
Personal respiratory protective devices: efficacy of Millipore and Whatman filters.个人呼吸防护设备:密理博和沃特曼过滤器的功效
J Med Assoc Thai. 2000 Feb;83(2):117-22.
6
The Ramathibodi nasal filter in a simulated human airway: evaluated with laser smoke particles and a laser diode dust portable monitor.
J Med Assoc Thai. 2001 Dec;84(12):1667-73.
7
Filtration efficiency of the ramathibodi nasal filter evaluated by rhinomanometry in high concentration level of laser smoke particle.
J Med Assoc Thai. 2002 Jul;85(7):772-7.
8
Experiment of intranasal synthetic filter for prevention of suspended particulated matter: rhinomanometric evaluation.用于预防悬浮颗粒物的鼻内合成过滤器实验:鼻阻力测量评估
J Med Assoc Thai. 1998 Aug;81(8):608-15.
9
Effect of protective filters on fire fighter respiratory health during simulated bushfire smoke exposure.模拟丛林火灾烟雾暴露期间防护过滤器对消防员呼吸健康的影响。
Am J Ind Med. 2006 Sep;49(9):740-50. doi: 10.1002/ajim.20369.
10
An in vitro analysis of a carotid artery stent with a protective porous membrane.一种带有保护性多孔膜的颈动脉支架的体外分析。
J Vasc Interv Radiol. 2004 Nov;15(11):1295-305. doi: 10.1097/01.RVI.0000141339.79538.0D.