• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Spiral CT optimization for measurement of bronchial lumen diameter using an experimental model.

作者信息

Edwards P D, Bull R K, Brown V S, Curtin J

机构信息

Department of Radiology, Addenbrooke's Hospital, Cambridge, UK.

出版信息

Br J Radiol. 2000 Jul;73(871):715-9. doi: 10.1259/bjr.73.871.11089461.

DOI:10.1259/bjr.73.871.11089461
PMID:11089461
Abstract

The aim of the study was to determine optimal parameters for demonstrating sublobar bronchi on spiral CT. Measurements were obtained from five parallel polyethylene tubes embedded in foam matrix with similar radiographic characteristics to segmental and subsegmental bronchi and to lung parenchyma, respectively. Collimation widths of 1.5, 2, 3 and 4 mm were used, with a pitch of 1 or 1.5 and a reconstruction interval of 1 mm or 2 mm. Various slice planes were used. Images acquired orthogonally were viewed normally. Images acquired in planes oblique or parallel to the long axes of the tubes were reformatted into a plane orthogonal to the long axes of the tubes to be comparable with the directly acquired orthogonal images. Tube diameters were measured at lung window settings (L, -400; W, 1300) and compared with known true inner and outer tube diameters. Measurements from images acquired orthogonal to the tube long axes were accurate regardless of slice thickness. Images acquired obliquely or parallel only produced accurate measurements at the lowest slice thickness (1.5 mm). Pitch and reconstruction interval had no effect on measurement error in any scan plane. It is concluded that a slice thickness of 1.5 mm or less, with a pitch of 1.5, should be used when acquiring images at angles other than orthogonal to the long axes of experimental tubes equivalent to the segmental and subsegmental bronchi. It is suggested that similar parameters should be used in vivo and that the examination should be targeted to the area of the bronchial tree in question to reduce patient dose and length of breath-hold.

摘要

相似文献

1
Spiral CT optimization for measurement of bronchial lumen diameter using an experimental model.
Br J Radiol. 2000 Jul;73(871):715-9. doi: 10.1259/bjr.73.871.11089461.
2
CT of a bronchial phantom. Factors affecting appearance and size measurements.
Invest Radiol. 1984 Sep-Oct;19(5):394-8. doi: 10.1097/00004424-198409000-00011.
3
Assessment of airways with three-dimensional quantitative thin-section CT: in vitro and in vivo validation.三维定量薄层CT对气道的评估:体外和体内验证
Radiology. 2007 Feb;242(2):563-72. doi: 10.1148/radiol.2422060029. Epub 2006 Dec 19.
4
[Spiral CT and 3-D reconstruction of the tracheobronchial tree for the selection of the proper double-lumen tubes before individual lung ventilation].
Rofo. 1997 Feb;166(2):159-61. doi: 10.1055/s-2007-1015399.
5
[Normal bronchi on high resolution CT].[高分辨率CT上的正常支气管]
Nihon Kyobu Shikkan Gakkai Zasshi. 1992 Mar;30(3):369-74.
6
Image quality of volume rendering of the bronchial tree: Kymogram-gated versus retrospectively ECG-gated and non-gated multi-row detector CT.支气管树容积再现的图像质量:记波摄影门控与回顾性心电图门控及非门控多排探测器CT的比较
Acad Radiol. 2005 Feb;12(2):173-81. doi: 10.1016/j.acra.2004.11.022.
7
Bronchial wall thickness: appropriate window settings for thin-section CT and radiologic-anatomic correlation.
Radiology. 1996 Jun;199(3):831-6. doi: 10.1148/radiology.199.3.8638013.
8
[Visualization of the normal bronchial system by computed tomography].[通过计算机断层扫描对正常支气管系统的可视化]
Digitale Bilddiagn. 1988 Sep;8(3):128-32.
9
High resolution volume imaging of airways and lung parenchyma with multislice CT.利用多层螺旋CT对气道和肺实质进行高分辨率容积成像。
Br J Radiol. 2004;77 Spec No 1:S98-105. doi: 10.1259/bjr/27596725.
10
Comparison of vertical and oblique CT in evaluation of bronchial tree.垂直CT与斜位CT在评估支气管树中的比较。
J Comput Assist Tomogr. 1988 Nov-Dec;12(6):956-62. doi: 10.1097/00004728-198811000-00009.

引用本文的文献

1
The comparison of the lengths and diameters of main bronchi measured from two-dimensional and three-dimensional images in the same patients.同一患者二维及三维图像测量主支气管长度及直径的比较。
Korean J Anesthesiol. 2014 Mar;66(3):189-94. doi: 10.4097/kjae.2014.66.3.189. Epub 2014 Mar 28.
2
Novel patterns for the growing main bronchi in the human fetus: an anatomical, digital and statistical study.人类胎儿主支气管生长的新模式:解剖学、数字与统计学研究
Surg Radiol Anat. 2014 Jan;36(1):55-65. doi: 10.1007/s00276-013-1145-x. Epub 2013 Jun 19.
3
Main bronchial diameters in patients with very severe COPD.
极重度 COPD 患者的主支气管直径。
J Anesth. 2010 Jun;24(3):359-65. doi: 10.1007/s00540-010-0924-3. Epub 2010 Mar 26.