Jachuck S J, Ramani P S, Clark F, Kalbag R M
Br Med J. 1975 Feb 1;1(5952):242-4. doi: 10.1136/bmj.1.5952.242.
Serial electrocardiographic (E.C.G.) recordings were taken in seven patients suffering from intracranial conditions, for which their intracranial pressure was directly and continuously monitored with a Konigsberg extradural transducer. The E.C.G. changes observed in patients with raised intracranial pressure were prominent U waves, ST-T segment changes, notched T waves, and shortening and prolongation of Q-T intervals. Two patients with normal intracranial pressure showed no E.C.G. abnormalities but also establish a relationship between E.C.G. abnormalities and changing intracranial pressure.