Jelińska A, Stanisz B, Zajac M, Musiał W, Ostrowicz A
Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Karol Marcinkowski University of Medical Sciences, 6 Grunwaldzka Str., 60-780 Poznań, Poland.
Acta Pol Pharm. 2000 May-Jun;57(3):171-3.
A HPLC method for the determination of the cetirizine dichloride in tablets was developed and validated. The determination was performed with a LiChrosorb RP-18 column, mobile phase of KH2PO4 (0.01 mol/l)--acetonitrile 65:35 (v/v), flow rate: 2 ml.min-1, UV detection at 230 nm and methyl paraben as an internal standard.