David R, Shtarker H, Horesh Z, Tsur A, Soudry M
Department of Orthopedic Surgery, Rabin Medical Center, Petah Tiqva, Israel.
Orthopedics. 2001 Jan;24(1):33-6. doi: 10.3928/0147-7447-20010101-15.
Thirteen patients with failed total knee arthroplasty (TKA) due to infection (12 patients) or aseptic loosening (1 patient) underwent arthrodesis using the Ilizarov external fixator. Solid fusion was achieved in all patients with an average healing time of 27.6 weeks. Patients spent an average 18.8 weeks in the fixator followed by an average 8.8 weeks in a plaster cylinder cast. Five patients had a pin tract infection and one a superficial wound infection. One patient had 15 degrees recurvatum after surgery that was gradually corrected by adding a hinge system to the fixator. Average shortening of the affected limb was 3.7 cm (range: 1-6 cm). The Ilizarov fixator for knee arthrodesis after failed TKA produced favorable results and should be considered for use by surgeons familiar with the technique.
13例因感染(12例)或无菌性松动(1例)导致全膝关节置换术(TKA)失败的患者接受了使用Ilizarov外固定架的关节融合术。所有患者均实现了牢固融合,平均愈合时间为27.6周。患者平均佩戴外固定架18.8周,随后平均在石膏管型中固定8.8周。5例患者发生针道感染,1例发生浅表伤口感染。1例患者术后出现15度膝反屈,通过在外固定架上增加铰链系统逐渐得到纠正。患侧肢体平均短缩3.7 cm(范围:1 - 6 cm)。TKA失败后使用Ilizarov固定架进行膝关节融合术取得了良好效果,熟悉该技术的外科医生应考虑使用。