Serial intravascular ultrasound analysis of the impact of lesion length on the efficacy of intracoronary gamma-irradiation for preventing recurrent in-stent restenosis.

作者信息

Ahmed J M, Mintz G S, Waksman R, Weissman N J, Leiboff B, Pichard A D, Satler L F, Kent K M, Leon M B

机构信息

Cardiovascular Research Institute, Washington Hospital Center, Washington, DC, USA.

出版信息

Circulation. 2001 Jan 16;103(2):188-91. doi: 10.1161/01.cir.103.2.188.

Abstract

BACKGROUND

The relation between lesion length and effectiveness of brachytherapy is not well studied.

METHODS AND RESULTS

We compared serial (postintervention and follow-up) intravascular ultrasound findings in 66 patients with native coronary artery in-stent restenosis (ISR) who were treated with (192)Ir (15 Gy delivered 2 mm away from the radiation source). Patients were enrolled in the Washington Radiation for In-Stent Restenosis Trial (WRIST; ISR length, 10 to 47 mm; n=36) or Long WRIST (ISR length, 36 to 80 mm; n=30). External elastic membrane, stent, lumen, and intimal hyperplasia (IH; stent minus lumen) areas and source-to-target (intravascular ultrasound catheter to external elastic membrane) distances were measured. Postintervention stent areas were larger in WRIST and smaller in Long WRIST patients (P:<0.0001). At follow-up, maximum IH area significantly increased in both WRIST and Long WRIST patients (P:<0.0001 for both), but this increase was greater in Long WRIST patients (P:=0.0006). Similarly, minimum lumen cross-sectional area significantly decreased in both WRIST and Long WRIST patients (P:<0.05 and P:<0.0001, respectively), but this decrease was more pronounced in Long WRIST patients (P:=0.0567). The maximum source-to-target distance was longer in Long WRIST than in WRIST, and it correlated directly with ISR length (r=0.547, P:<0.0001). Overall, the change in minimum lumen area and the change in maximum IH area correlated with the maximum source-to-target distance (r=0.352, P:=0.0038 and r=0.523, P:<0.0001 for WRIST and Long WRIST, respectively). The variability (maximum/minimum) in IH area at follow-up also correlated with the maximum source-to-target distance (r=0.378, P:<0.0001).

CONCLUSIONS

Brachytherapy may be less effective in longer ISR lesions because of the greater variability and longer source-to-target distances in diffuse ISR.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验