A rapid, rugged, and highly specific assay for the quantitation of cocaine (COC) and especially its primary metabolites benzoylecgonine (BZE) and ecgonine methyl ester (EME) in human urine has been established. Here, we investigated the use of on-line sample extraction coupled to rapid chromatography systems for tandem mass analysis of COC, EME, and BZE in human urine. Using this method, sample preparation consisted of a sole centrifugation step. Combined extraction and chromatographic run times were < 3.5 min. The lower limits of detection were 0.5 ng/mL, 2.0 ng/mL, and 0.5 ng/mL for EME, BZE, and COC, respectively. Linear calibration curves ranging from 7.5 ng/mL to 1000 ng/mL were produced for the test analytes. Within-day and between-day precision and accuracy of the assay were determined using human urine quality-control specimens at 5, 10, or 15; 150; and 1000 ng/mL. The analyses were performed over the course of five days, rendering %CVs < 10% for EME, BZE, and COC. Percent mean accuracy for the three analytes of 97 to 113% were obtained. Our data suggest that on-line sample extraction coupled with rapid high-performance liquid chromatography-tandem mass spectrometry may be a viable alternative for EME, BZE, and COC analyses in human urine.
已建立一种快速、耐用且高度特异的方法,用于定量检测人尿液中的可卡因(COC),特别是其主要代谢物苯甲酰爱康宁(BZE)和爱康宁甲酯(EME)。在此,我们研究了在线样品萃取与快速色谱系统联用,用于人尿液中COC、EME和BZE的串联质谱分析。使用该方法,样品制备仅包括一个离心步骤。萃取和色谱运行总时间<3.5分钟。EME、BZE和COC的检测下限分别为0.5 ng/mL、2.0 ng/mL和0.5 ng/mL。针对测试分析物生成了7.5 ng/mL至1000 ng/mL的线性校准曲线。使用浓度为5、10或15;150;以及1000 ng/mL的人尿液质量控制样本,测定了该检测方法的日内和日间精密度与准确度。分析在五天内进行,EME、BZE和COC的变异系数(%CV)均<10%。三种分析物的平均准确度百分比为97%至113%。我们的数据表明,在线样品萃取与快速高效液相色谱 - 串联质谱联用可能是分析人尿液中EME、BZE和COC的一种可行替代方法。