Hoyer O
Wahnbachtalsperrenverband, DVGW-Prüflabor für UV-Anlagen, Postfach 1933, 53709 Siegburg.
Schriftenr Ver Wasser Boden Lufthyg. 2000;108:79-92.
UV disinfection has become a practical and safely validatable disinfection procedure by specifying the requirements for testing and monitoring in DVGW standard W 294. A standardized biodosimetric testing procedure and monitoring with standardized UV sensors is introduced and successfully applied. On-line monitoring of irradiance can be counterchecked with handheld reference sensors and makes it possible that UV systems can be used for drinking water disinfection with the same level of confidence and safety as is conventional chemical disinfection.