Suppr超能文献

交感神经刺激对犬脑和头部血流的影响。

Effect of sympathetic nerve stimulation on cerebral and cephalic blood flow in dogs.

作者信息

Traystman R J, Rapela C E

出版信息

Circ Res. 1975 May;36(5):620-30. doi: 10.1161/01.res.36.5.620.

Abstract

The effect of sympathetic stimulation (stellate ganglion) on dog cerebral and cephalic blood flows was studied via a cervical or a thoracic approach to the stellate ganglion under sodium pentobarbital or chloralose anesthesia. Two different stimulation voltages (3v and 5v) of monophasic pulses were applied for 1 minute. Venous outflow was measured at the confluence of the sagittal, straight and lateral sinuses with the lateral sinuses occluded and with them patent. When the lateral sinuses were occluded, stellate ganglion stimulation resulted in a marked decrease in common carotid blood flow to 38 plus or minus 2.5% (SE) of control and dilation of the ipsilateral pupil, but cerebral blood flow did not change. Similar effects were observed with each of the anatomic approaches, anesthetics, and voltages used and in dogs with low cerebral vascular tone induced by hypercapnia. When the lateral sinuses were kept patent, sympathetic nerve stimulation decreased the venous outflow to 89 plus or minus 2.9% of control and clamping both of the external jugular veins increased venous outflow to 120 plus or minus 2.7% of control. When the lateral sinuses were kept patent and the extracranial venous pressure was increased by clamping both of the external jugular veins, the decrease in venous outflow in response to sympathetic stimulation was even larger: venous outflow was only 65 plus or minus 4.9% of control. We conclude that stimulation of the stellate ganglion has no effect on the cerebral vasculature. Sympathetic stimulation significantly decreases venous blood flow measured at the confluence of the sinuses only when communications between the intracranial and extracranial venous vasculatures are present.

摘要

在戊巴比妥钠或氯醛糖麻醉下,通过颈段或胸段途径刺激犬星状神经节,研究交感神经刺激(星状神经节)对犬脑血流和头部血流的影响。施加两种不同的单相脉冲刺激电压(3伏和5伏),持续1分钟。在矢状窦、直窦和外侧窦汇合处测量静脉流出量,分别在外侧窦闭塞和开放的情况下进行。当外侧窦闭塞时,刺激星状神经节会导致颈总动脉血流显著减少至对照值的38±2.5%(标准误),同侧瞳孔扩大,但脑血流无变化。在所使用的每种解剖学途径、麻醉剂和电压下,以及在因高碳酸血症导致脑血管张力降低的犬中,均观察到类似效应。当外侧窦保持开放时,交感神经刺激会使静脉流出量减少至对照值的89±2.9%,而夹闭双侧颈外静脉会使静脉流出量增加至对照值的120±2.7%。当外侧窦保持开放且通过夹闭双侧颈外静脉使颅外静脉压升高时,交感神经刺激引起的静脉流出量减少更为明显:静脉流出量仅为对照值的65±4.9%。我们得出结论,刺激星状神经节对脑血管系统无影响。只有当颅内和颅外静脉血管系统之间存在连通时,交感神经刺激才会显著降低在窦汇合处测量的静脉血流。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验