To assess the effect of a hinged ankle foot orthosis (AFO) on functional mobility and gait impairments in people with a severe hemiplegia undergoing rehabilitation, and to investigate the patients' views of the hinged AFO.
With/without group comparison, and face-to-face questionnaire.
Twenty-five subjects over 18 years, with a hemiplegia following cerebrovascular accident (CVA) undergoing rehabilitation in a regional rehabilitation unit.
Functional Ambulation Categories as a measure of disability. Paper walkways to measure gait impairments--stride length, step length, symmetry, cadence and velocity. Face-to-face questionnaire to determine the users' opinion of the hinged AFO.
Comparison of gait with and without the hinged AFO showed significant improvements in functional mobility (p = 0.000) and in some gait impairments; stride length of the weak (p < 0.005, 95% CI -8.1, -1.6) and sound legs (p < 0.014, 95% CI -8, -1), velocity (p = 0.00, 95% CI -0.1, -0.03) and cadence (p < 0.002, 95% CI -15.1, -3.8). No effect was found for step length in the weak or sound leg or symmetry. The subjects' response was positive, 24 (96%) felt they walked better with the AFO and found it comfortable. Twenty-three (92%) were unbothered by the appearance and 16 (64%) could doff and don it.
The hinged AFO improved objective measures of gait impairments and disability and patients were positive about it.
评估一种带铰链的踝足矫形器(AFO)对正在接受康复治疗的重度偏瘫患者功能活动能力和步态障碍的影响,并调查患者对带铰链AFO的看法。
有/无该矫形器组对比以及面对面问卷调查。
25名18岁以上因脑血管意外(CVA)导致偏瘫且正在某地区康复机构接受康复治疗的患者。
采用功能步行分类法评估残疾程度。使用纸质步道测量步态障碍——步幅、步长、对称性、步频和速度。通过面对面问卷调查确定使用者对带铰链AFO的意见。
对比佩戴和不佩戴带铰链AFO时的步态发现,功能活动能力(p = 0.000)及一些步态障碍有显著改善;患侧(p < 0.005,95%可信区间-8.1,-1.6)和健侧(p < 0.014,95%可信区间-8,-1)的步幅、速度(p = 0.00,95%可信区间-0.1,-0.03)和步频(p < 0.002,95%可信区间-15.1,-3.8)均有改善。患侧或健侧的步长及对称性未发现有变化。患者反应良好,24名(96%)感觉佩戴AFO时行走更好且感觉舒适。23名(92%)对其外观不在意,16名(64%)能够自行穿脱。
带铰链的AFO改善了步态障碍和残疾的客观指标,患者对其评价良好。