Suppr超能文献

[通过毛细血管显微镜检查和激光多普勒血流仪评估糖尿病患者的微循环改变]

[Assessment of diabetic alterations of microcirculation by means of capillaroscopy and laser-Doppler anemometry].

作者信息

Meyer M F, Pfohl M, Schatz H

机构信息

Medizinische Klinik, Universitätsklinik Bergmannsheil, Ruhr-Universität Bochum.

出版信息

Med Klin (Munich). 2001 Feb 15;96(2):71-7. doi: 10.1007/pl00002181.

Abstract

BACKGROUND

Only minor changes of skin capillary morphology have been described in diabetic patients by means of capillaroscopy, whereas cutaneous microvascular dysfunction is well known. We examined correlations between functional and morphological abnormalities of the capillaries in Type 1 and 2 diabetic patients and the influence of diabetes duration on capillary morphology.

PATIENTS AND METHODS

Density, diameters and morphology of nailfold capillaries were investigated in diabetic patients, 16 Type 1 and 19 Type 2, and compared to age- and sex-matched control groups. Capillary blood cell velocities (CBV) during rest and after 3-minute arterial occlusion were measured in the dorsal middle phalangeal area of the left ring finger by means of laser Doppler anemometry.

RESULTS

Capillary density, width and arterial limb diameter were similar in Type 1 and 2 diabetic patients compared to their controls. Capillary diameters of the apical part and the venous limb were enlarged in the combined analysis of Type 1 and 2 diabetic patients compared to the control group (apex: 19.2 +/- 0.6 microns vs 17.4 +/- 0.6 microns, p = 0.0243; venous limb: 17.3 +/- 0.5 microns vs 15.9 +/- 0.4 microns, p = 0.0238). Tortuous capillaries were more often observed in Type 1 (n = 13 vs n = 7, p = 0.028) and 2 diabetic patients (n = 16 vs n = 9, p = 0.019) than in controls. In Type 1 diabetic patients an inverse correlation (r = -0.52; p = 0.019) was found between capillary density and resting CBV. In Type 2 diabetic patients capillary apex diameter correlated positively with peak CBV (r = 0.49; p = 0.017). Disease duration correlated inversely with arterial limb diameter (r = -0.48; p = 0.020) and width of the capillaries (r = -0.48; p = 0.018) in Type 2 diabetic patients.

CONCLUSION

Tortuous and dilated capillaries, indicating microangiopathy, were found in the skin of diabetic patients by means of capillaroscopy. Using laser Doppler anemometry it is possible to assess impairment of postocclusive reactive hyperemia, due to diabetic microvascular dysfunction, in single capillaries. Correlations between morphological and functional microcirculatory alterations in diabetes may be explained by hemodynamic changes, depending on diabetes duration.

摘要

背景

通过毛细血管镜检查,仅发现糖尿病患者皮肤毛细血管形态有轻微变化,而皮肤微血管功能障碍却是众所周知的。我们研究了1型和2型糖尿病患者毛细血管功能与形态异常之间的相关性,以及糖尿病病程对毛细血管形态的影响。

患者与方法

对16例1型糖尿病患者和19例2型糖尿病患者的甲襞毛细血管密度、直径和形态进行了研究,并与年龄和性别匹配的对照组进行比较。通过激光多普勒血流仪测量左手环指背侧中节指骨区域静息时和动脉阻断3分钟后的毛细血管血细胞速度(CBV)。

结果

与对照组相比,1型和2型糖尿病患者的毛细血管密度、宽度和动脉支直径相似。在1型和2型糖尿病患者的综合分析中,与对照组相比,顶端和静脉支的毛细血管直径增大(顶端:19.2±0.6微米对17.4±0.6微米,p = 0.0243;静脉支:17.3±0.5微米对15.9±0.4微米,p = 0.0238)。1型糖尿病患者(n = 13对n = 7,p = 0.028)和2型糖尿病患者(n = 16对n = 9,p = 0.019)比对照组更常观察到毛细血管迂曲。在1型糖尿病患者中,毛细血管密度与静息CBV之间存在负相关(r = -0.52;p = 0.019)。在2型糖尿病患者中,毛细血管顶端直径与CBV峰值呈正相关(r = 0.49;p = 0.017)。在2型糖尿病患者中,病程与动脉支直径(r = -0.48;p = 0.020)和毛细血管宽度(r = -0.48;p = 0.018)呈负相关。

结论

通过毛细血管镜检查发现糖尿病患者皮肤中存在迂曲和扩张的毛细血管,提示微血管病变。使用激光多普勒血流仪可以评估由于糖尿病微血管功能障碍导致的单次毛细血管闭塞后反应性充血的损害。糖尿病中形态学和功能性微循环改变之间的相关性可能由血流动力学变化来解释,这取决于糖尿病病程。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验