Comparison of wire reinforced tubes with warmed standard tubes to facilitate fiberoptic intubation.

作者信息

Connelly N R, Kyle R, Gotta J, Calimaran A, Robbins L D, Kanter G, Dunn S M

机构信息

Department of Anesthesiology, Baystate Medical Center, Springfield, MA 01199, USA.

出版信息

J Clin Anesth. 2001 Feb;13(1):3-5. doi: 10.1016/s0952-8180(00)00224-5.

Abstract

STUDY OBJECTIVE

To compare the ease of insertion of a warmed standard tracheal tube to that of a wire reinforced tracheal tube when placed over a flexible fiberoptic bronchoscope.

DESIGN

Randomized controlled trial.

SETTING

Tertiary care hospital.

PATIENTS

50 patients undergoing elective general anesthesia.

INTERVENTIONS

Patients' tracheas were intubated with a flexible fiberoptic bronchoscope and had either a standard or wire-reinforced tracheal tube inserted. If resistance was met, the tube was withdrawn, rotated, and readvanced. This was repeated two times. If unsuccessful, the flexible fiberoptic bronchoscope was removed, and intubation was attempted with the other type of tracheal tube.

MEASUREMENTS

The ability to advance the tracheal tube was determined.

MAIN RESULTS

There were no demographic differences between the two groups. There was a similar ease of advancement of the two tracheal tubes.

CONCLUSIONS

When performing elective flexible fiberoptic bronchoscopy for intubation, we recommend using the less expensive warmed standard tracheal tube.