Liu A, Cui Y, Huang H
Department of Otolaryngology, Tongji Hospital of Tongji Medical University, Wuhan 430030.
Lin Chuang Er Bi Yan Hou Ke Za Zhi. 1998 Oct;12(10):435-8.
With ILO-92 Otodynamics Analyzer, distortion product otoacoustic emissions (DPOAEs) at the 2 f1-f2 frequency were recorded from 86 normally hearing ears in response to four groups of different primary levels (L1 = L2 = 75 dB SPL; L1 = L2 = 65 dB SPL; L1 = L2 = 60 dB SPL; L1 = 65 dB SPL, L2 = 50 dB SPL). The average DPOAEs-gram demonstrated a bilobed contour with two peaks at approximately 1.5 kHz and 5 kHz and "notch" between 2.5 kHz and 3 kHz. Moreover, the contour of DPOAEs-gram had no obvious changes with sex, ear or primary stimulus levels differences. While the primary levels increased, the amplitude of DPOAEs gradually increased, which was about 55-65 dB SPL below the primary levels. At each frequency from 1-6 kHz, statistical analysis showed that there existed significantly different DPOAEs level under four groups of different primary stimulus levels.
使用国际劳工组织92型耳动力学分析仪,对86只听力正常的耳朵记录了2f1 - f2频率下的畸变产物耳声发射(DPOAE),以响应四组不同的初始声压级(L1 = L2 = 75 dB SPL;L1 = L2 = 65 dB SPL;L1 = L2 = 60 dB SPL;L1 = 65 dB SPL,L2 = 50 dB SPL)。平均DPOAE图谱呈现出双峰轮廓,在约1.5 kHz和5 kHz处有两个峰值,在2.5 kHz和3 kHz之间有“凹陷”。此外,DPOAE图谱的轮廓在性别、耳朵或初始刺激声压级差异方面没有明显变化。随着初始声压级增加,DPOAE的幅度逐渐增加,比初始声压级低约55 - 65 dB SPL。在1 - 6 kHz的每个频率上,统计分析表明在四组不同的初始刺激声压级下,DPOAE水平存在显著差异。