Suppr超能文献

三环类抗抑郁药过量后的心脏内传导缺陷

Intracardiac conduction defects following overdose of tricyclic antidepressant drugs.

作者信息

Vohra J, Hunt D, Burrows G, Sloman G

出版信息

Eur J Cardiol. 1975 Apr;2(4):443-52.

PMID:1126353
Abstract

Atrioventricular and intraventricular conduction were assessed in 4 patients with tricyclic antidepressant overdosage. The proximal or A-V nodal conduction (A-H) was normal, but 3 patients showed a drug-related increase in the QRS duration and His-Purkinje (H-V) conduction time. One patient with a normal H-V interval had a normal width QRS. The findings were independent of the heart rate and suggested a "quinidine-like effect" of the tricyclic drugs when ingested in suicidal doses. All 4 patients had normal intracardic conduction when restudied 8 days later. Procainamide and quinidine have similar effects on the intracardiac conduction and would appear undesirable in the treatment of cardiac arrhythmias in patients with tricyclic overdosage. Practolol in a dose of 20 mg by intravenous injection reduced the heart rate and caused a relative increase in the A-H interval but did not affect either the distal atrioventricular or intraventricular conduction. Although there was a slight drop in blood pressure, it may be a safer drug to use.

摘要

对4例三环类抗抑郁药过量患者的房室和心室内传导进行了评估。近端或房室结传导(A-H)正常,但3例患者的QRS时限和希氏-浦肯野(H-V)传导时间出现与药物相关的增加。1例H-V间期正常的患者QRS宽度正常。这些发现与心率无关,提示三环类药物在自杀剂量摄入时具有“奎尼丁样效应”。8天后再次研究时,所有4例患者的心内传导均正常。普鲁卡因胺和奎尼丁对心内传导有类似作用,在三环类药物过量患者的心律失常治疗中似乎不合适。静脉注射20mg剂量的心得宁可降低心率,并使A-H间期相对增加,但不影响远端房室或心室内传导。尽管血压略有下降,但它可能是一种更安全的用药。