Suppr超能文献

使用鼻内咪达唑仑喷雾剂预防磁共振成像引起的幽闭恐惧症。

Using intranasal midazolam spray to prevent claustrophobia induced by MR imaging.

作者信息

Hollenhorst J, Münte S, Friedrich L, Heine J, Leuwer M, Becker H, Piepenbrock S

机构信息

Department of Anaesthesiology, Medical School of Hannover, Carl-Neuberg-Str. 1, 30625 Hannover, Germany.

出版信息

AJR Am J Roentgenol. 2001 Apr;176(4):865-8. doi: 10.2214/ajr.176.4.1760865.

Abstract

OBJECTIVE

Up to 37% of patients undergoing MR imaging examinations experience moderate to severe levels of anxiety that necessitate the termination of the procedure in 5-10% of patients. Although the clinical use of MR imaging has increased, effective procedures to handle claustrophobia are lacking. We evaluated the effectiveness of intranasally administered midazolam spray in preventing claustrophobic responses of patients undergoing MR imaging.

SUBJECTS AND METHODS

Fifty-four patients scheduled for MR imaging were included in this prospective study. Anxiety and sedation of patients were evaluated before drug administration, immediately before MR imaging, and at the end of the procedure. The Spielberger State-Trait Anxiety Inventory, the visual analogue scale of anxiety, and a five-point sedation scale were used. Half the patients received intranasal spray applications of 4 mg midazolam, whereas the other patients received a placebo, in a randomized, double-blind study design (six sprayings of 0.5% midazolam solution or NaCl 0.9%, respectively). The intensity of the sensation of burning of the nasal mucosa was rated by patients using a three-point scale (no, slight, or strong burning). The quality of scan images was evaluated by a radiologist using a five-point scale (0 = extremely poor, 5 = excellent).

RESULTS

No cancellations occurred with patients who received midazolam, whereas four of 27 patients receiving placebo panicked and terminated the scanning procedure. The initial anxiety and sedation scores did not differ between the groups. Patients who received midazolam spray were more sedated and less anxious immediately before entering the MR scanner and reported a more intense slight transient burning of the nasal mucosa than those in the placebo group. The quality of the MR image was higher in the midazolam group.

CONCLUSION

A sizeable reduction in MR imaging-related anxiety and improved MR image quality were seen with patients who received intranasal midazolam spray. With the exception of transient burning of the nasal mucosa, no adverse effects were reported. This simple and safe method is useful in sedating patients for MR imaging and other minor procedures.

摘要

目的

高达37%接受磁共振成像(MR)检查的患者会经历中度至重度焦虑,5% - 10%的患者因此需要终止检查。尽管MR成像的临床应用有所增加,但缺乏有效应对幽闭恐惧症的方法。我们评估了经鼻给予咪达唑仑喷雾剂在预防接受MR成像患者的幽闭恐惧反应方面的有效性。

受试者与方法

本前瞻性研究纳入了54名计划接受MR成像的患者。在给药前、即将进行MR成像前以及检查结束时评估患者的焦虑和镇静情况。使用斯皮尔伯格状态 - 特质焦虑量表、焦虑视觉模拟量表和五点镇静量表。在随机双盲研究设计中,一半患者接受4毫克咪达唑仑经鼻喷雾给药,而其他患者接受安慰剂(分别为6次喷雾0.5%咪达唑仑溶液或0.9%氯化钠溶液)。患者使用三点量表对鼻粘膜灼烧感强度进行评分(无、轻微或强烈灼烧)。放射科医生使用五点量表评估扫描图像质量(0 = 极差,5 = 优秀)。

结果

接受咪达唑仑的患者中没有出现检查取消的情况,而接受安慰剂的27名患者中有4人恐慌并终止了扫描程序。两组患者最初的焦虑和镇静评分没有差异。接受咪达唑仑喷雾的患者在进入MR扫描仪前镇静程度更高、焦虑程度更低,并且报告鼻粘膜轻微短暂灼烧感比安慰剂组更强烈。咪达唑仑组的MR图像质量更高。

结论

接受经鼻咪达唑仑喷雾的患者在与MR成像相关的焦虑方面有显著降低,且MR图像质量有所改善。除了鼻粘膜短暂灼烧外,未报告有不良反应。这种简单安全的方法对于为接受MR成像及其他小手术的患者进行镇静很有用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验