Suppr超能文献

主动脉支架植入对顺应性和血流的影响。一项在猪身上的实验研究。

The effect of implantation of aortic stents on compliance and blood flow. An experimental study in pigs.

作者信息

Pihkala J, Thyagarajan G K, Taylor G P, Nykanen D, Benson L N

机构信息

Department of Pediatrics, The Hospital for Sick Children, The University of Toronto School of Medicine, Ontario, Canada.

出版信息

Cardiol Young. 2001 Mar;11(2):173-81. doi: 10.1017/s1047951101000075.

Abstract

Balloon dilation of coarctation of the aorta has been found to be an effective modality for treatment. Recently, in the older child and adult, implantation of endovascular stents has been considered a clinical alternative to dilation alone. Little is known, however, of the effect of implantation of stents on aortic compliance. To investigate this impact of implantation, we studied 18 piglets, divided into experimental and control groups. At median weight of 14 kg, 2 pairs of ultrasonic crystals were implanted on the aortic wall. After 1 week, all animals underwent catheterization. In the experimental group, a 3 cm long balloon expandable stent was implanted in the descending thoracic aorta between the pairs of crystals. Measurements of arterial pressure and dimensions were performed before implantation and immediately thereafter, and at follow-up catheterization. The index of stiffness, beta, and the the elastic modulus of aortic pressure-strain, were calculated as indexes of arterial compliance. The change in compliance during the period of study was not different between groups. At follow-up, no difference was observed between groups in the velocity of the aortic pulse wave, the augmentation index, or the maximum velocity of flow of blood. The stents remained patent and did not affect aortic growth or medial wall thickness. There was no difference between groups in levels of plasma renin activity and serum aldosterone. In this animal model studied over the short term, therefore, implantation of stents does not affect aortic compliance. Further studies are required to elucidate the long term effects of stents on the hemodynamics affecting the aortic wall and local flow dynamics.

摘要

主动脉缩窄的球囊扩张已被证明是一种有效的治疗方式。最近,对于年龄较大的儿童和成人,血管内支架植入已被视为单纯扩张的一种临床替代方法。然而,关于支架植入对主动脉顺应性的影响却知之甚少。为了研究植入的这种影响,我们对18只小猪进行了研究,将其分为实验组和对照组。在平均体重为14千克时,在主动脉壁上植入两对超声晶体。1周后,所有动物均接受导管插入术。在实验组中,在晶体对之间的降主动脉中植入一个3厘米长的球囊可扩张支架。在植入前、植入后即刻以及随访导管插入术时进行动脉压力和尺寸测量。计算刚度指数β和主动脉压力-应变弹性模量作为动脉顺应性指标。在研究期间,两组之间的顺应性变化没有差异。随访时,两组在主动脉脉搏波速度、增强指数或血流最大速度方面均未观察到差异。支架保持通畅,并且不影响主动脉生长或中膜壁厚度。两组之间的血浆肾素活性水平和血清醛固酮水平没有差异。因此,在这个短期研究的动物模型中,支架植入不影响主动脉顺应性。需要进一步研究以阐明支架对影响主动脉壁的血流动力学和局部血流动力学的长期影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验