Suppr超能文献

头颈部隐匿性原发性肿瘤:铊201单光子发射计算机断层扫描与计算机断层扫描和/或磁共振成像的准确性

Occult primary tumors of the head and neck: accuracy of thallium 201 single-photon emission computed tomography and computed tomography and/or magnetic resonance imaging.

作者信息

van Veen S A, Balm A J, Valdés Olmos R A, Hoefnagel C A, Hilgers F J, Tan I B, Pameijer F A

机构信息

The Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam, the Netherlands.

出版信息

Arch Otolaryngol Head Neck Surg. 2001 Apr;127(4):406-11. doi: 10.1001/archotol.127.4.406.

Abstract

OBJECTIVE

To determine the accuracy of thallium 201 single-photon emission computed tomography (thallium SPECT) and computed tomography and/or magnetic resonance imaging (CT/MRI) in the detection of occult primary tumors of the head and neck.

DESIGN

Study of diagnostic tests.

SETTING

National Cancer Institute, Amsterdam, the Netherlands.

PATIENTS AND METHODS

Thirty-two patients with a neck node metastasis of an epithelial tumor and negative findings by mirror examination at initial presentation were included in the study. Twenty-nine patients underwent thallium SPECT and CT/MRI before examination under general anesthesia (EUA). In 3 patients only thallium SPECT was performed before EUA. Histological confirmation of an occult primary tumor during EUA was used as the gold standard. Negative radiodiagnostic and nuclear findings in the upper aerodigestive tract in the presence of a primary carcinoma other than of the head and neck were interpreted as true-negative findings.

RESULTS

For thallium SPECT the following results were recorded: sensitivity, 67%; specificity, 69%; accuracy, 69%; positive predictive value, 33%; and negative predictive value, 90%. In 1 patient, thallium whole body scan indicated a primary carcinoma beyond the mucosal lining of the upper aerodigestive tract. The CT/MRI results were as follows: sensitivity, 71%; specificity, 73%; accuracy, 72%; positive predictive value, 45%; and negative predictive value, 89%.

CONCLUSIONS

Thallium SPECT and CT/MRI showed comparable results for detection of occult primary tumors of the head and neck. A potential advantage of thallium SPECT is that it allows total body screening.

摘要

目的

确定铊201单光子发射计算机断层扫描(铊SPECT)以及计算机断层扫描和/或磁共振成像(CT/MRI)在检测头颈部隐匿性原发性肿瘤方面的准确性。

设计

诊断试验研究。

地点

荷兰阿姆斯特丹国家癌症研究所。

患者和方法

本研究纳入了32例上皮性肿瘤颈部淋巴结转移且初诊时镜检结果为阴性的患者。29例患者在全身麻醉检查(EUA)前接受了铊SPECT和CT/MRI检查。3例患者在EUA前仅进行了铊SPECT检查。EUA期间隐匿性原发性肿瘤的组织学确诊被用作金标准。在上呼吸道消化道存在非头颈部原发性癌的情况下,放射诊断和核检查结果为阴性被解释为真阴性结果。

结果

铊SPECT的检查结果如下:灵敏度为67%;特异度为69%;准确度为69%;阳性预测值为33%;阴性预测值为90%。1例患者的铊全身扫描显示上呼吸道消化道黏膜层以外存在原发性癌。CT/MRI的结果如下:灵敏度为71%;特异度为73%;准确度为72%;阳性预测值为45%;阴性预测值为89%。

结论

铊SPECT和CT/MRI在检测头颈部隐匿性原发性肿瘤方面显示出可比的结果。铊SPECT的一个潜在优势是它可以进行全身筛查。