Suppr超能文献

连续流动固相肽合成的压力监测

Pressure monitoring of continuous-flow solid-phase peptide synthesis.

作者信息

Baru M B, Mustaeva L G, Vagenina I V, Gorbunova E Y, Cherskii V V

机构信息

Branch of Shemyakin and Ovchinikov Institute of Bioorganic Chemistry, Russian Academy of Sciences, Puschino.

出版信息

J Pept Res. 2001 Mar;57(3):193-202. doi: 10.1111/j.1399-3011.2001.00774.x.

Abstract

We describe the noninvasive real-time pressure monitoring of Boc- and Fmoc-based peptide synthesis. Pressure was measured using a resistance strain gauge attached to the inlet of a continuous-flow reactor of variable volume. In the assembly of the 'difficult' polyalanine sequence, it was shown that pressure monitoring can reveal structural variations of the peptide-resin, e.g. the onset, development and termination of aggregation. This method provided washing minimization that favored substantial saving of solvents. The obtained results demonstrated the advantage of pressure monitoring over swellographic monitoring.

摘要

我们描述了基于Boc和Fmoc的肽合成的非侵入性实时压力监测。使用连接到可变体积连续流动反应器入口的电阻应变仪测量压力。在“困难的”聚丙氨酸序列的组装过程中,结果表明压力监测可以揭示肽-树脂的结构变化,例如聚集的开始、发展和终止。该方法实现了洗涤的最小化,有利于大量节省溶剂。所得结果证明了压力监测相对于膨胀成像监测的优势。