Nimmon C C, McAlister J M, Cattell W R
Br J Radiol. 1975 Apr;48(568):286-90. doi: 10.1259/0007-1285-48-568-286.
The distribution of kidney position in the sitting posture has been determined in a series of patients presenting for renography, using radiographic and ultrasonic techniques. Both the craniocaudal distribution of kidney centre positions and the distribution of the differences in depth below the posterior skin surface of the two kidney centres have been found to have a significant standard deviation. The effect of these distributions on the measurement of relative effective renal plasma flow by 131-I Hippuran probe renography has been calculated for the situation in which no kidney localizing techniques are used. The resulting error distribution has an SD of 21.7 per cent in the case of equally divided function.
利用放射照相和超声技术,对一系列接受肾造影检查的患者确定了坐姿时肾脏位置的分布情况。已发现肾脏中心位置的头尾分布以及两个肾脏中心在背部皮肤表面以下深度差异的分布均具有显著的标准差。对于未使用肾脏定位技术的情况,已计算出这些分布对通过131碘马尿酸探针肾造影测量相对有效肾血浆流量的影响。在功能均等的情况下,所得误差分布的标准差为21.7%。