Suppr超能文献

胰岛素泵与血糖调节。

Insulin pumps and glucose regulation.

作者信息

Thompson J S, Duckworth W C

机构信息

Department of Surgery, University of Nebraska Medical Center, 983280 Nebraska Medical Center, Omaha, Nebraska 68198-3280, USA.

出版信息

World J Surg. 2001 Apr;25(4):523-6. doi: 10.1007/s002680020347. Epub 2001 Apr 11.

Abstract

With recent technologic advances there has been a resurgence of interest in implantable insulin infusion devices. A satisfactory closed loop system has been elusive. Open loop systems include the pump, delivery catheter, and patient pump communicator. Several such systems are currently undergoing clinical investigation. Implantable pumps can be placed with minimal morbidity. Insulin underdelivery is the most frequent long-term problem. Several recent studies suggest that implantable pumps can safely and effectively maintain good glucose control. The development of a satisfactory implantable closed loop system will be the next step in this technology.

摘要

随着最近的技术进步,人们对可植入胰岛素输注装置的兴趣再度兴起。一个令人满意的闭环系统一直难以实现。开环系统包括泵、输送导管和患者泵通信器。目前有几种这样的系统正在进行临床研究。可植入泵的植入发病率极低。胰岛素输送不足是最常见的长期问题。最近的几项研究表明,可植入泵能够安全有效地维持良好的血糖控制。开发出令人满意的可植入闭环系统将是这项技术的下一步发展方向。