Since loading is increasingly believed to be a determining factor in the treatment outcome with oral implants, there is a need to expand the knowledge related to the biomechanics of oral implants and its influencing factors.
The aim of this study was to investigate the influence of prosthesis material on the distribution and magnitude of load on oral implants carrying a fixed partial prosthesis by in vivo quantification and qualification of this load.
Eight patients with in total nine three-unit fixed partial prostheses on three implants and three patients with in total four two-unit fixed partial prostheses on two implants were selected. Both metal and acrylic resin prostheses were made. Strain gauged abutments were used to measure the load on the supporting implants during controlled load application of 50 N on several positions along the occlusal surface of the prostheses and during maximal biting in maximal occlusion. Additional tests were conducted when the three-unit prostheses were supported only by two implants, thereby creating an extension pontic.
A significantly better distribution of bending moments with the metal prostheses in comparison to the acrylic resin prostheses was observed in the case of the three-unit prostheses on two implants. No other difference in load or load distribution with the different prosthesis materials was noted.
The clinical significance of the study reveals an increased risk for bending overload of the implants that are closest to the point of load application only in the case of acrylic resin long span prostheses or acrylic resin prostheses with extensions.
由于负荷越来越被认为是口腔种植体治疗结果的决定性因素,因此有必要拓展与口腔种植体生物力学及其影响因素相关的知识。
本研究的目的是通过对负荷进行体内定量和定性分析,研究修复体材料对承载固定局部义齿的口腔种植体上负荷分布和大小的影响。
选择8例患者,共在3颗种植体上制作9个三单位固定局部义齿,以及3例患者,共在2颗种植体上制作4个两单位固定局部义齿。制作了金属和丙烯酸树脂两种修复体。使用应变片基台在沿修复体咬合面的几个位置施加50N的控制负荷时以及在最大咬合时的最大咬合力时测量支持种植体上的负荷。当三单位修复体仅由两颗种植体支持从而形成延伸桥体时,进行了额外的测试。
在两颗种植体上的三单位修复体中,与丙烯酸树脂修复体相比,观察到金属修复体的弯矩分布明显更好。未发现不同修复体材料在负荷或负荷分布上有其他差异。
该研究的临床意义表明,仅在丙烯酸树脂长跨度修复体或带有延伸部分的丙烯酸树脂修复体的情况下,最靠近负荷施加点的种植体发生弯曲过载的风险增加。