Ozlü O, Türker A K, Ozgün G, Soykan I
Department of Anaesthesia, SSK Ankara Children Hospital, Ankara, Turkey.
Paediatr Anaesth. 2001 Jul;11(4):425-9. doi: 10.1046/j.1460-9592.2001.00685.x.
Distal oesophageal pH was measured during controlled ventilation in children with the laryngeal mask airway (LMATM), tracheal tube (TT) and face mask (FM).
Fifty-six children scheduled for inguinal surgery with a standardized general anaesthetic technique were randomly allocated to receive LMA (n=21), TT (n=18) or FM (n=19). A 14 Fr pH probe was placed into the distal oesophagus and pH values were measured over 1 min at 2-min intervals during the first 20 min of anaesthesia.
The median values of pH were 4.4 (3.5-5.5), 4.2 (3.3-4.9), 4.1 (3.2-5.1), 4.1 (3.3-5.0), 4.0 (3.3-4.9), 4.0 (3.4-5.1); 4.2 (3.3-5.1), 4.2 (3.6-5.0), 4.2 (3.5-5.0), 4.2 (3.5-5.2), 4.2 (3.5-5.0), 4.1 (3.5-5.0) and 4.2 (3.6-5.0), 4.2 (3.8-5.8), 4.1 (2.8-5.2), 4.2 (3.3-5.1), 4.2 (3.4-5.1), 4.3 (3.4-5.1) for LMA, TT and FM groups, respectively.
There was no difference in the median pH values, within and between the groups (P > 0.05). We conclude that there is no difference in gastro-oesophageal reflux, when using a LMA, TT or FM during controlled ventilation in anaesthetized children.
在使用喉罩气道(LMATM)、气管导管(TT)和面罩(FM)对儿童进行控制通气期间,测量食管远端pH值。
56例计划行腹股沟手术且采用标准化全身麻醉技术的儿童被随机分配接受喉罩(n = 21)、气管导管(n = 18)或面罩(n = 19)。将一根14 Fr的pH探头置于食管远端,在麻醉的前20分钟内,每隔2分钟测量1分钟的pH值。
喉罩组、气管导管组和面罩组的pH中位数分别为4.4(3.5 - 5.5)、4.2(3.3 - 4.9)、4.1(3.2 - 5.1)、4.1(3.3 - 5.0)、4.0(3.3 - 4.9)、4.0(3.4 - 5.1);4.2(3.3 - 5.1)、4.2(3.6 - 5.0)、4.2(3.5 - 5.0)、4.2(3.5 - 5.2)、4.2(3.5 - 5.0)、4.1(3.5 - 5.0)以及4.2(3.6 - 5.0)、4.2(3.8 - 5.8)、4.1(2.8 - 5.2)、4.2(3.3 - 5.1)、4.2(3.4 - 5.1)、4.3(3.4 - 5.1)。
组内和组间的pH中位数无差异(P > 0.05)。我们得出结论,在对麻醉儿童进行控制通气时,使用喉罩、气管导管或面罩时,胃食管反流无差异。