John M T, Zwijnenburg A J
Department of Prosthodontics, Martin Luther University Halle-Wittenberg, Grosse Steinstrasse 19, 06108 Halle, Saale, Germany.
Int J Prosthodont. 2001 May-Jun;14(3):265-70.
The aim of this report was to study the ability of examiners to measure reliably the clinical signs of temporomandibular disorders (TMD). Four examiners participated in this study of 11 TMD patients and 25 nonpatients.
Vertical and lateral excursions of the jaw were measured using a millimeter ruler. Joint sounds during vertical jaw movements were assessed using digital palpation. The reliability of delivering appropriate degrees of digital pressure to assess masticatory muscle pain was assessed using a manometer after training examiners to exert specified pressures.
Intraclass correlation coefficients for the measurement of vertical and protrusive jaw movements were > or = 0.87, which was considered excellent. The intraclass correlation coefficient for measurements of left and right lateral jaw excursions varied between 0.73 and 0.85, which was considered acceptable. The interobserver agreement for detecting the joint sounds showed overall agreement across examiners of 78%. Kappa for every possible pair of examiners varied between .52 and .86 (median .75, interquartile range .18). Reliability for diagnostic categories from the Helkimo index and Research Diagnostic Criteria for Temporomandibular Disorders involving joint noises showed modest reliability.
Point estimates and measures of spread for reliability measures of single clinical TMD signs as well as combinations of signs into diagnostic categories from the Helkimo index and Research Diagnostic Criteria for Temporomandibular Disorders involving joint noises were sufficient in a group of four examiners.
本报告旨在研究检查者可靠测量颞下颌关节紊乱病(TMD)临床体征的能力。四名检查者参与了这项针对11名TMD患者和25名非患者的研究。
使用毫米尺测量下颌的垂直和侧向运动。在垂直下颌运动过程中,通过数字触诊评估关节弹响。在培训检查者施加特定压力后,使用压力计评估施加适当程度数字压力以评估咀嚼肌疼痛的可靠性。
测量垂直和前伸下颌运动的组内相关系数≥0.87,被认为是优秀的。测量左右侧向下颌运动的组内相关系数在0.73至0.85之间,被认为是可接受的。检查者之间检测关节弹响的一致性显示,检查者之间的总体一致性为78%。每对可能的检查者的Kappa值在0.52至0.86之间(中位数0.75,四分位间距0.18)。来自赫尔基莫指数和颞下颌关节紊乱病研究诊断标准中涉及关节弹响的诊断类别的可靠性显示出适度的可靠性。
在一组四名检查者中,单个临床TMD体征的可靠性测量以及从赫尔基莫指数和颞下颌关节紊乱病研究诊断标准中涉及关节弹响的体征组合成诊断类别的点估计和离散度测量是足够的。