The use of salting-out effect for the off-line preconcentration of charged analytes in capillary electrophoresis is demonstrated for the first time. Using benzalkonium chloride (BAK) as model compound, a mixture of cationic surfactants consisting of even-numbered alkylbenzyl quaternary ammonium homologues (C8-C18), the addition of appropriate amounts of sodium chloride and acetonitrile in the sample solution (2 mL sample volume) was found to be capable of providing ca. 40-fold enhancement in detection sensitivity. In addition to affording a preconcentrating effect due to the extraction of BAK in the smaller volume water-miscible organic solvent phase (acetonitrile), the organic solvent also serves to improve the peak area and shape of the longer chain surfactants. Optimal experimental conditions, such as volume of acetonitrile and concentration of sodium chloride, for the preconcentration of BAK with good preconcentration factors and reproducibility were investigated. The usefulness of the present method was demonstrated for the improved determination of BAK present in commercially available industrial and pharmaceutical products.

摘要

首次证明了利用盐析效应在毛细管电泳中对带电分析物进行离线预富集。以苯扎氯铵(BAK)为模型化合物,使用由偶数烷基苄基季铵同系物(C8 - C18)组成的阳离子表面活性剂混合物,发现在样品溶液(2 mL样品体积)中加入适量的氯化钠和乙腈能够使检测灵敏度提高约40倍。除了由于BAK在较小体积的与水混溶的有机溶剂相(乙腈)中萃取而产生预富集效果外,有机溶剂还有助于改善长链表面活性剂的峰面积和峰形。研究了用于BAK预富集的最佳实验条件,如乙腈体积和氯化钠浓度,以获得良好的预富集因子和重现性。本方法的实用性通过对市售工业和医药产品中BAK的改进测定得到了证明。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验