Suppr超能文献

髋臼盂唇的磁共振关节造影:放射状重建的价值

Magnetic resonance arthrography of the acetabular labrum: value of radial reconstructions.

作者信息

Plötz G M, Brossmann J, von Knoch M, Muhle C, Heller M, Hassenpflug J

机构信息

Klinik für Orthopädie, Christian-Albrechts-Universität, Kiel, Germany.

出版信息

Arch Orthop Trauma Surg. 2001 Sep;121(8):450-7. doi: 10.1007/s004020100270.

Abstract

The intention was to compare the sensitivity and specificity of radial planes with oblique coronal and oblique axial planes for the detection of labral abnormalities of the acetabulum on magnetic resonance arthrography (MRa). Twenty cadaveric hip joints were examined by radiography and MRa. For MRa, 15 ml of a solution of iodinated contrast material and gadolinium diethylene triamine tetra-acetic acid (Gd-DTPA; 100:1) were injected under fluoroscopic guidance. MRI was performed on a 1.5-T MR scanner with a fat-suppressed 3D-FLASH sequence (TR/TE/flip-angle 42 ms/10 ms/40 degrees; field of view 16 cm, matrix 256 x 256, section thickness 1.5 mm, pixel size 0.7 x 0.7 mm). Multiplanar image reconstructions were done perpendicular to the acetabulum in oblique coronal and oblique axial planes and in radial planes. Macroscopic and histopathologic examination of the labral specimens was performed. Labral lesions were found in 15/20 hips (75%) on pathologic examination. Six hips demonstrated labral degeneration. The labrum was partially detached in 7 hips and completely detached in 2 hips. A flap-like labrum was found in 2 cases, 1 with partial detachment of the labrum and 1 with a degenerated labrum. Using oblique coronal and oblique axial reconstructions, pathologic findings were confirmed by MRa in 9/15 specimens (sensitivity 60%). There were no false-positive findings (specificity 100%, accuracy 70%). Also, 3/6 labral degenerations without detachment, 4/7 partial detachments, and 2/2 complete detachments were correctly diagnosed. Two flap-like labra were not recognized. With radial reconstructions, pathologic findings were correctly confirmed in 12/15 specimens (sensitivity 80%) without false-positive findings (specificity 100%, accuracy 85%). Also, 3/6 labral degenerations without detachment, 6/7 partial detachments, 2/2 complete detachments, and 1/2 flap-like labra were correctly diagnosed. MRa of the acetabular labrum using radial reconstructions is well suited to delineate the acetabular labrum and to diagnose labral detachments. Radial reconstructions allow for perpendicular display of the whole acetabular circumference and are more accurate for the diagnosis of acetabular labral lesions, when compared with oblique coronal and oblique axial reconstructions.

摘要

目的是比较在磁共振关节造影(MRa)中,用于检测髋臼盂唇异常的桡平面与斜冠状面和斜轴面的敏感性和特异性。对20个尸体髋关节进行了X线摄影和MRa检查。对于MRa,在透视引导下注入15毫升碘化造影剂和钆二乙烯三胺四乙酸(Gd-DTPA;100:1)溶液。在1.5-T MR扫描仪上采用脂肪抑制3D-FLASH序列(TR/TE/翻转角42毫秒/10毫秒/40度;视野16厘米,矩阵256×256,层厚1.5毫米,像素大小0.7×0.7毫米)进行MRI检查。在斜冠状面、斜轴面和桡平面上进行垂直于髋臼的多平面图像重建。对盂唇标本进行了大体和组织病理学检查。病理检查发现20个髋关节中有15个(75%)存在盂唇病变。6个髋关节显示盂唇退变。7个髋关节盂唇部分分离,2个髋关节盂唇完全分离。2例发现瓣状盂唇,1例盂唇部分分离,1例盂唇退变。使用斜冠状面和斜轴面重建,MRa在15个标本中的9个(敏感性60%)证实了病理结果。无假阳性结果(特异性100%,准确性70%)。此外,6个无分离的盂唇退变中有3个、7个部分分离中有4个以及2个完全分离中有2个被正确诊断。2个瓣状盂唇未被识别。采用桡平面重建,15个标本中的12个(敏感性80%)正确证实了病理结果,无假阳性结果(特异性100%,准确性85%)。此外,6个无分离的盂唇退变中有3个、7个部分分离中有6个、2个完全分离中有2个以及2个瓣状盂唇中有1个被正确诊断。使用桡平面重建的髋臼盂唇MRa非常适合描绘髋臼盂唇并诊断盂唇分离。与斜冠状面和斜轴面重建相比,桡平面重建允许垂直显示整个髋臼圆周,并且对髋臼盂唇病变的诊断更准确。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验