• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Drawdown and stream depletion produced by pumping in the vicinity of a partially penetrating stream.

作者信息

Butler J J, Zlotnik V A, Tsou M S

机构信息

Kansas Geological Survey, 1930 Constant Ave., Campus West, University of Kansas, Lawrence, KS 66047, USA.

出版信息

Ground Water. 2001 Sep-Oct;39(5):651-9. doi: 10.1111/j.1745-6584.2001.tb02354.x.

DOI:10.1111/j.1745-6584.2001.tb02354.x
PMID:11554242
Abstract

Commonly used analytical approaches for estimation of pumping-induced drawdown and stream depletion are based on a series of idealistic assumptions about the stream-aquifer system. A new solution has been developed for estimation of drawdown and stream depletion under conditions that are more representative of those in natural systems (finite width stream of shallow penetration adjoining an aquifer of limited lateral extent). This solution shows that the conventional assumption of a fully penetrating stream will lead to a significant overestimation of stream depletion (> 100%) in many practical applications. The degree of overestimation will depend on the value of the stream leakance parameter and the distance from the pumping well to the stream. Although leakance will increase with stream width, a very wide stream will not necessarily be well represented by a model of a fully penetrating stream. The impact of lateral boundaries depends upon the distance from the pumping well to the stream and the stream leakance parameter. In most cases, aquifer width must be on the order of hundreds of stream widths before the assumption of a laterally infinite aquifer is appropriate for stream-depletion calculations. An important assumption underlying this solution is that stream-channel penetration is negligible relative to aquifer thickness. However, an approximate extension to the case of nonnegligible penetration provides reasonable results for the range of relative penetrations found in most natural systems (up to 85%). Since this solution allows consideration of a much wider range of conditions than existing analytical approaches, it could prove to be a valuable new tool for water management design and water rights adjudication purposes.

摘要

相似文献

1
Drawdown and stream depletion produced by pumping in the vicinity of a partially penetrating stream.
Ground Water. 2001 Sep-Oct;39(5):651-9. doi: 10.1111/j.1745-6584.2001.tb02354.x.
2
Pumping-induced drawdown and stream depletion in a leaky aquifer system.渗漏含水层系统中抽水引起的水位下降和河流枯竭
Ground Water. 2007 Mar-Apr;45(2):178-86. doi: 10.1111/j.1745-6584.2006.00272.x.
3
Analytical model for aquifer response incorporating distributed stream leakage.考虑分布式河流渗漏的含水层响应分析模型。
Ground Water. 2002 Jul-Aug;40(4):378-84. doi: 10.1111/j.1745-6584.2002.tb02516.x.
4
Stream-aquifer interactions: evaluation of depletion volume and residual effects from ground water pumping.河流-含水层相互作用:地下水抽取的亏缺量及残留效应评估
Ground Water. 2002 May-Jun;40(3):284-90. doi: 10.1111/j.1745-6584.2002.tb02656.x.
5
Semi-Analytical Modeling of Transient Stream Drawdown and Depletion in Response to Aquifer Pumping.对含水层抽汲响应的瞬态井流降落和疏干的半解析建模。
Ground Water. 2024 Nov-Dec;62(6):904-919. doi: 10.1111/gwat.13425. Epub 2024 Jul 4.
6
Semianalytical solutions for stream depletion in partially penetrating streams.部分穿透河流中水流亏缺的半解析解
Ground Water. 2004 Jan-Feb;42(1):92-6. doi: 10.1111/j.1745-6584.2004.tb02454.x.
7
Drawdown and stream depletion produced by pumping in the vicinity of a partially penetrating stream.在部分穿透河流附近抽水所产生的水位下降和水流枯竭。
Ground Water. 2006 Mar-Apr;44(2):142-3; discussion 143. doi: 10.1111/j.1745-6584.2006.00169.x.
8
Adjoint simulation of stream depletion due to aquifer pumping.含水层抽汲引起的水流枯竭的伴随模拟。
Ground Water. 2012 Sep-Oct;50(5):746-53. doi: 10.1111/j.1745-6584.2011.00901.x. Epub 2011 Dec 19.
9
Pumping test evaluation of stream depletion parameters.河流流量减少参数的抽水试验评估
Ground Water. 2006 Jul-Aug;44(4):540-6. doi: 10.1111/j.1745-6584.2006.00212.x.
10
Flow depletion in a small stream caused by ground water abstraction from wells.因从井中抽取地下水导致的小河流流量减少。
Ground Water. 2002 Jul-Aug;40(4):425-37. doi: 10.1111/j.1745-6584.2002.tb02521.x.