Ann Plast Surg. 2001 Oct;47(4):367-80. doi: 10.1097/00000637-200110000-00002.

Abstract

The objective of this study was to assess the accuracy of magnetic resonance imaging (MRI) in detecting silicone breast implant rupture, and to explore implications of the use of MRI for screening and estimating the prevalence of rupture among asymptomatic women. The study consisted of a meta-analysis of published studies with the calculation of sensitivity and specificity as independent parameters, the summary receiver operating characteristic (ROC) curve, and other clinically important values such as positive predictive value (PPV) and negative predictive value. Participants included women with breast implants who underwent both MRI and subsequent implant removal. Eighteen studies, performed primarily in academic settings, with approximately 1,039 women and 2,036 implants met entry criteria. Most studies involved women with symptomatic implants. Assuming that sensitivity and specificity were independent parameters, the summary sensitivity was 78% (95% confidence interval [CI], 71-83) and the summary specificity was 91% (95% CI, 86-94). Using ROC meta-analysis methodology, the odds ratio describing the overall accuracy of the test was 40.1 (range, 18.8-85.4). There was substantial heterogeneity across studies. Studies using breast coils, those with convenience samples, larger studies, and studies of lower report quality tended to report higher levels of accuracy. The quality of study reports was generally poor. Among symptomatic women, PPV was fairly high. Among lower prevalence populations, PPV appeared to be insufficient to warrant use as a screening tool. MRI is moderately accurate in detecting silicone breast implant rupture. However, MRI should remain a confirmatory diagnostic test and should not be used to screen asymptomatic women.

摘要

本研究的目的是评估磁共振成像(MRI)检测硅胶乳房植入物破裂的准确性,并探讨使用MRI进行筛查以及估计无症状女性中破裂发生率的意义。该研究包括对已发表研究的荟萃分析,计算敏感性和特异性作为独立参数、汇总接受者操作特征(ROC)曲线以及其他临床重要值,如阳性预测值(PPV)和阴性预测值。参与者包括接受了MRI检查并随后取出植入物的乳房植入女性。18项主要在学术环境中进行的研究,涉及约1039名女性和2036个植入物,符合纳入标准。大多数研究涉及有症状植入物的女性。假设敏感性和特异性为独立参数,汇总敏感性为78%(95%置信区间[CI],71 - 83),汇总特异性为91%(95%CI,86 - 94)。使用ROC荟萃分析方法,描述该测试总体准确性的优势比为40.1(范围,18.8 - 85.4)。各研究之间存在显著异质性。使用乳房线圈的研究、采用便利样本的研究、规模较大的研究以及报告质量较低的研究往往报告的准确性水平较高。研究报告的质量普遍较差。在有症状的女性中,PPV相当高。在患病率较低的人群中,PPV似乎不足以作为筛查工具。MRI在检测硅胶乳房植入物破裂方面具有中等准确性。然而,MRI应仍然是一种确诊诊断测试,不应被用于筛查无症状女性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验