Chandler A C
Am J Ophthalmol. 1975 Sep;80(3 Pt 2):522-4. doi: 10.1016/0002-9394(75)90220-2.
I modified the conjunctivodacryocystostomy procedure in 36 patients (43 eyes) by directly threading the pre-flanged PE-190 polyethylene tubing over a No. 3 or 4 Bowman probe into and through the nasolacrimal duct, contrary to the original intranasal maneuvers. This simplified the procedure but caused minor amenable complications such as shortening the tubing postoperatively. In eight of 43 eyes, replacement or shortening the tubing was easily done in the office over a handleless Bowman probe. In three of the 43 eyes, polyethylene tubing was occasionally plugged, requiring cleansing or replacement. Of the 43 tubes inserted, 42 are still in place and functioning.
我对36例患者(43只眼)的结膜泪囊造口术进行了改良,与原来的鼻腔内操作不同,我直接将带凸缘的PE - 190聚乙烯管套在3号或4号鲍曼探针上,插入并穿过鼻泪管。这简化了手术,但引起了一些轻微的可处理并发症,如术后管道缩短。在43只眼中,有8只眼通过无柄鲍曼探针在门诊很容易地完成了管道更换或缩短。在43只眼中,有3只眼的聚乙烯管偶尔堵塞,需要清洗或更换。在插入的43根管道中,42根仍在位且功能正常。