Suppr超能文献

基于与阴道镜检查结果比较的宫颈细胞学检查设备(细胞清扫器)评估。

Evaluation of a cervical cytology device (cell-sweep) based on comparison to colposcopic findings.

作者信息

Kieswetter C, Hernandez E, Anderson L, Heller P B

机构信息

Division of Gynecologic Oncology, Allegheny University Hospital for Women, Philadelphia, Pennsylvania, USA.

出版信息

J Natl Med Assoc. 2001 Nov;93(11):436-9.

Abstract

A new cytology sampling device, the CellSweep, identifies squamous intraepithelial lesions with a sensitivity of 75%. The purpose of this study was to evaluate the accuracy of cervical cytology using a new sampling device combining an endocervical brush and ectocervical spatula into one unit (CellSweep, patented by R. Mohajer, Troy, Michigan). From April 1995 to July 1995, 71 patients referred to the Allegheny University Hospitals Colposcopy Clinic had cervical cytology obtained with the CellSweep and underwent colposcopic evaluation of the cervix. The ability of the CellSweep to detect an abnormality confirmed by colposcopic evaluation was studied. Colposcopically directed ectocervical biopsies were obtained only in patients with identifiable lesions (n = 32). No random biopsies were obtained. The cytology smear was unsatisfactory for interpretation in one case. The remaining 70 Papanicolaou smears were read as normal in 17 (24%) cases and atypical squamous cells in 19 (27%). A squamous intraepithelial lesion (SIL) was detected in 34 (48%) smears. The colposcopic evaluation was normal in 50 patients who had satisfactory Papanicolaou smears, whereas SIL was detected in 20 cases. In 31 patients, SIL was not present in either colposcopy or cytology. In this preliminary study, the CellSweep identified SIL with a sensitivity of 75% and a specificity of 62%. The CellSweep, which combines an endocervical brush and an ectocervical spatula into a single unit, seems to be an acceptable device for obtaining cervical cells for cytologic screening.

摘要

一种新型细胞学采样装置——细胞清扫器(CellSweep),识别鳞状上皮内病变的灵敏度为75%。本研究的目的是评估一种新型采样装置用于宫颈细胞学检查的准确性,该装置将宫颈管刷和宫颈外口刮片组合在一个单元中(细胞清扫器,由密歇根州特洛伊市的R. Mohajer申请专利)。1995年4月至1995年7月,71名转诊至阿勒格尼大学医院阴道镜诊所的患者使用细胞清扫器进行了宫颈细胞学检查,并接受了宫颈阴道镜评估。研究了细胞清扫器检测经阴道镜评估证实的异常的能力。仅对有可识别病变的患者(n = 32)进行了阴道镜引导下的宫颈外口活检。未进行随机活检。有1例细胞学涂片无法满意解读。其余70张巴氏涂片,17例(24%)判读为正常,19例(27%)为非典型鳞状细胞。在34例(48%)涂片中检测到鳞状上皮内病变(SIL)。50例巴氏涂片满意的患者阴道镜评估正常,而20例检测到SIL。31例患者在阴道镜检查和细胞学检查中均未发现SIL。在这项初步研究中,细胞清扫器识别SIL的灵敏度为75%,特异度为62%。将宫颈管刷和宫颈外口刮片组合在一个单元中的细胞清扫器,似乎是一种可接受的用于获取宫颈细胞进行细胞学筛查的装置。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验