Dubiel W T, Cullhed I
Scand J Thorac Cardiovasc Surg. 1975;9(2):108-19. doi: 10.3109/14017437509139183.
Thirty-five patients with a frame-supported autologous fascia lata graft implanted in the aortic annulus were investigated 11 to 36 months after operation. The group comprised 7 patients with pure aortic stenosis, 11 with combined stenosis and incompetence and 17 with pure aortic incompetence. Seven patients had concommitant mitral valve disease. The follow-up investigation included ECG, a work test on a bicycle ergometer, dynamic spirometry, roentgenological heart volume determination and haematological "screening tests" for intravascular haemolysis. Concomitant with a marked subjective improvement of the patients, there was a considerable objective improvement, as judged by physical working capacity, ECG signs of left ventricular hypertrophy and heart volume. The serum haptoglobin values were somewhat lower postoperatively (mean value 44 mg%), but no ahaptoglobinaemia occurred. Thus, no definite signs of intravascular haemolysis were noted. No thrombo-embolism occurred within this observation period, despite the fact that none of the patients with isolated aortic valve replacement were treated with anticoagulants. This investigation shows that a frame-supported autologous fascia lata valvular graft in the aorta can function well during a period of up to 3 years.
对35例在主动脉瓣环植入带支架自体阔筋膜移植片的患者在术后11至36个月进行了研究。该组包括7例单纯主动脉瓣狭窄患者、11例狭窄合并关闭不全患者和17例单纯主动脉瓣关闭不全患者。7例患者伴有二尖瓣疾病。随访检查包括心电图、自行车测力计运动试验、动态肺量测定、X线心脏容积测定以及血管内溶血的血液学“筛查试验”。与患者主观上的显著改善相一致,从体力工作能力、左心室肥厚的心电图表现和心脏容积判断,客观上也有相当大的改善。术后血清触珠蛋白值略低(平均值44mg%),但未出现无触珠蛋白血症。因此,未发现血管内溶血的确切迹象。在该观察期内未发生血栓栓塞,尽管接受单纯主动脉瓣置换的患者均未接受抗凝治疗。这项研究表明,主动脉带支架自体阔筋膜瓣膜移植片在长达3年的时间内可良好发挥功能。