Serial change of the coronary flow velocity reserve was evaluated with fast velocity-encoded cine magnetic resonance imaging (MRI) for noninvasive detection of restenosis after coronary stent implantation.
In total, 60 MRI flow studies were performed in 10 patients with coronary artery disease who undersvent elective successful stent implantation to the lesion in the proximal left anterior descending artery. Flow velocities in the segment that was distal to the stent were measured before and after intravenous injection of dipyridamole. MRI measurements of coronary flow velocity reserve were repeated every 4 weeks for 6 months, and follow-up angiography was performed 6 months after the procedure.
In patients without restenosis (n = 7, % diameter stenosis: 27.8%+/-7.1) at follow-up angiography, the coronary flow velocity reserve remained normal during the 6-month follow-up time. The flow velocity reserve was 2.31+/-0.30 at 1 month and 2.52+/-0.25 at 6 months after stent implantation (p = NS). In contrast, the coronary flow velocity reserve showed a significant decrease after 4 months in patients with restenosis (n = 3, % diameter stenosis: 66.3%+/-8.1) at follow-up angiography. The flow velocity reserve was 2.26+/-0.49 at 1 month and 1.52+/-0.09 at 6 months after stent implantation (p < 0.05).
Fast velocity-encoded cine MRI is a technique that shows promise in providing non-invasive detection of restenosis of coronary stent implantation.
采用快速速度编码电影磁共振成像(MRI)评估冠状动脉血流速度储备的系列变化,以无创检测冠状动脉支架植入术后再狭窄。
对10例成功接受选择性支架植入术治疗左前降支近端病变的冠心病患者共进行了60次MRI血流研究。在静脉注射双嘧达莫前后测量支架远端节段的血流速度。冠状动脉血流速度储备的MRI测量每4周重复一次,持续6个月,并在术后6个月进行随访血管造影。
在随访血管造影中无再狭窄的患者(n = 7,直径狭窄百分比:27.8%±7.1)中,冠状动脉血流速度储备在6个月的随访期间保持正常。支架植入后1个月时血流速度储备为2.31±0.30,6个月时为2.52±0.25(p =无显著性差异)。相比之下,在随访血管造影中有再狭窄的患者(n = 3,直径狭窄百分比:66.3%±8.1)中,冠状动脉血流速度储备在4个月后显著降低。支架植入后1个月时血流速度储备为2.26±0.49,6个月时为1.52±0.09(p < 0.05)。
快速速度编码电影MRI是一种在无创检测冠状动脉支架植入术后再狭窄方面显示出前景的技术。