Suppr超能文献

Magnetic resonance spectroscopic imaging-guided brachytherapy for localized prostate cancer.

作者信息

DiBiase Steven J, Hosseinzadeh Keya, Gullapalli Rao P, Jacobs Stephen C, Naslund Michael J, Sklar Geoffrey N, Alexander Richard B, Yu Cedric

机构信息

Department of Radiation Oncology, University of Maryland Medical Center, Baltimore, MD 21201, USA.

出版信息

Int J Radiat Oncol Biol Phys. 2002 Feb 1;52(2):429-38. doi: 10.1016/s0360-3016(01)02609-8.

Abstract

PURPOSE

Prostate brachytherapy (PB) entails the placement of radioactive sources throughout the entire prostate gland to treat localized cancer. Typically, the target volume in PB encompasses the entire prostate gland because of the inability to localize the cancer and the multifocal nature of this malignancy. However, because of the unique biochemical nature of the prostate gland, recent advances in magnetic resonance spectroscopic imaging (MRSI) of the prostate have allowed precise delineation of the cancer location within the prostate gland. This report reveals our initial experience of MRSI-guided PB.

METHODS

A MRSI study was obtained in 15 localized prostate cancer patients before their scheduled PB. The results of this study were used to internally map 7 x 7 x 9-mm volumes of prostate tissue to assign cancerous areas a higher dose of radiation. Such tumor-bearing areas had a low citrate/(choline+creatine) ratio consistent with cancer. On the basis of the anatomic MRI and MRSI correlation, three-dimensional coordinates were assigned to the locations of MRSI-defined cancer. The entire target volume was treated to a standard prescription dose using I-125 or Pd-103. Abnormal citrate regions, termed the biologic tumor volume, were prescribed a dose of 130% of the target volume dose to dose escalate in the abnormal citrate regions while respecting the normal radiation tolerances of the surrounding areas. Three-dimensional treatment planning was used to perform the implant.

RESULTS

Of the 15 prostate cancer patients evaluated, all had successful three-dimensional MRSI acquisition before their scheduled PB procedure. In 14 of the 15 patients planned with MRSI, the data were successfully incorporated into their treatment planning and were used to increase the radiation dose prescription to 130% in the MRSI-defined volumes. In 1 patient, MRSI revealed significant background artifact that made a focal boost impractical. Postimplant dosimetry confirmed a median V100 of 95% (range 72%-100%) in the 15 evaluated patients for the prescription dose. Furthermore, the median BTV100 for the abnormal citrate region was 90% (range 80-100%) as determined by postimplant dosimetry. Urethral and rectal dose-volume histograms were within normal limits. Morbidity was comparable with that for conventionally treated patients.

CONCLUSION

MRSI offers a promising new approach for the delivery of ionizing radiation in PB. Although this series was small and with a short follow-up, MRSI-guided implants are feasible and warrant further investigation as a means of improving the therapeutic ratio in PB [corrected].

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验