Suppr超能文献

成功的准分子原位角膜磨镶术后人眼角膜的组织学和超微结构发现

Histologic and ultrastructural findings in human corneas after successful laser in situ keratomileusis.

作者信息

Anderson Nicole J, Edelhauser Henry F, Sharara Nariman, Thompson Keith P, Rubinfeld Roy S, Devaney Dawn M, L'Hernault Nancy, Grossniklaus Hans E

机构信息

L. F. Montgomery Ophthalmic Pathology Laboratory, BT428 Emory Eye Center, 1365 Clifton Rd, Atlanta, GA 30322, USA.

出版信息

Arch Ophthalmol. 2002 Mar;120(3):288-93. doi: 10.1001/archopht.120.3.288.

Abstract

OBJECTIVE

To examine the histologic and ultrastructural features of human corneas after successful laser in situ keratomileusis (LASIK) in 2 patients post mortem.

METHODS

Portions of 4 corneas were processed for histology, transmission electron microscopy, and scanning electron microscopy.

RESULTS

Case 1 had undergone LASIK 3 months prior to death and case 2 had undergone LASIK 20 months prior to death. A Hansatome (Bausch & Lomb Surgical Inc, Clarement, Calif) microkeratome with a 180-microm plate had been used for case 1 and an Automated Corneal Shaper (Chiron Corporation, Munich, Germany) with a 160-microm plate had been used for case 2. Histologically, the LASIK flap measured 160 microm and 150 microm in thickness in case 1 and case 2, respectively. Corneas from both cases exhibited minor epithelial ingrowth into the wound, reactive keratocytes at the wound margin, irregular collagen fibrils in the wound bed, and severed collagen bundles at the flap hinge. These findings were more pronounced in case 1 than in case 2, and the wound interface was virtually imperceptible in case 2. Additionally, the corneas from case 1 contained periodic acid-Schiff--positive electron dense material and wide-spaced collagen at the wound interface, and there was an absence of corneal nerves.

CONCLUSIONS

These findings show that changes caused by wound repair that are present at 3 months are minor 20 months after LASIK.

摘要

目的

对2例死后成功接受准分子原位角膜磨镶术(LASIK)的人眼角膜进行组织学和超微结构特征研究。

方法

对4只角膜的部分组织进行组织学、透射电子显微镜和扫描电子显微镜检查。

结果

病例1在死亡前3个月接受了LASIK手术,病例2在死亡前20个月接受了LASIK手术。病例1使用的是配有180微米刀片的Hansatome(博士伦外科公司,加利福尼亚州克莱蒙特)微型角膜刀,病例2使用的是配有160微米刀片的自动角膜成型仪(奇龙公司,德国慕尼黑)。组织学检查显示,病例1和病例2的LASIK角膜瓣厚度分别为160微米和150微米。两例角膜均表现为伤口处有少量上皮内生、伤口边缘有反应性角膜细胞、伤口床胶原纤维不规则以及角膜瓣铰链处胶原束断裂。这些表现病例1比病例2更明显,病例2的伤口界面几乎难以察觉。此外,病例1的角膜在伤口界面处含有过碘酸希夫染色阳性的电子致密物质和宽间距胶原,且无角膜神经。

结论

这些发现表明,LASIK术后3个月出现的伤口修复引起的变化在20个月时较轻。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验