Obes Res. 2002 Mar;10(3):150-7. doi: 10.1038/oby.2002.24.

Abstract

OBJECTIVE

This study was designed to validate accelerometer-based activity monitors against energy expenditure (EE) in children; to compare monitor placement sites; to field-test the monitors; and to establish sedentary, light, moderate, and vigorous threshold counts.

RESEARCH METHODS AND PROCEDURES

Computer Science and Applications Actigraph (CSA) and Mini-Mitter Actiwatch (MM) monitors, on the hip or lower leg, were validated and calibrated against 6-hour EE measurements by room respiration calorimetry, activity by microwave detector, and heart rate by telemetry in 26 children, 6 to 16 years old. During the 6 hours, the children performed structured activities, including resting metabolic rate (RMR), Nintendo, arts and crafts, aerobic warm-up, Tae Bo, treadmill walking and running, and games. Activity energy expenditure (AEE) computed as EE - RMR was regressed against counts to derive threshold counts.

RESULTS

The mean correlations between EE or AEE and counts were slightly higher for MM-hip (r = 0.78 +/- 0.06) and MM-leg (r = 0.80 +/- 0.05) than CSA-hip (r = 0.66 +/- 0.08) and CSA-leg (r = 0.73 +/- 0.07). CSA and MM performed similarly on the hip (inter-instrument r = 0.88) and on the lower leg (inter-instrument r = 0.89). Threshold counts for the CSA-hip were <800, <3200, <8200, and > or = 8200 for sedentary, light, moderate, and vigorous categories, respectively. For the MM-hip, the threshold counts were <100, <900, <2200, and > or = 2200, respectively.

DISCUSSION

The validation of the CSA and MM monitors against AEE and their calibration for sedentary, light, moderate, and vigorous thresholds certify these monitors as valid, useful devices for the assessment of physical activity in children.

摘要

目的

本研究旨在验证基于加速度计的活动监测器在儿童中与能量消耗(EE)的相关性;比较监测器的放置部位;对监测器进行现场测试;并确定久坐、轻度、中度和剧烈活动的阈值计数。

研究方法与步骤

在26名6至16岁儿童中,将计算机科学与应用公司的Actigraph(CSA)和Mini-Mitter公司的Actiwatch(MM)监测器分别佩戴在臀部或小腿上,通过房间呼吸热量测定法测量6小时的能量消耗、用微波探测器测量活动量以及通过遥测测量心率,对这两种监测器进行验证和校准。在这6小时内,儿童进行了结构化活动,包括静息代谢率(RMR)、玩任天堂游戏、手工艺活动、有氧热身、跆拳道、在跑步机上行走和跑步以及玩游戏。将计算得出的活动能量消耗(AEE,即EE - RMR)与计数进行回归分析,以得出阈值计数。

结果

MM-臀部(r = 0.78 +/- 0.06)和MM-小腿(r = 0.80 +/- 0.05)的EE或AEE与计数之间的平均相关性略高于CSA-臀部(r = 0.66 +/- 0.08)和CSA-小腿(r = 0.73 +/- 0.07)。CSA和MM在臀部(仪器间r = 0.