通气模式对表面活性剂缺乏肺脏在不同全氟碳剂量下部分液体通气期间气体交换的影响。

Effect of ventilation mode on gas exchange during partial liquid ventilation at different perfluorocarbon doses in surfactant-depleted lung.

作者信息

Lim C M, Yang S H, Kang J L, Koh Y

机构信息

Division of Respiratory and Critical Care Medicine, University of Ulsan College of Medicine, Seoul, Korea 138-600.

出版信息

Lung. 2001;179(4):245-55. doi: 10.1007/s004080000065.

Abstract

Although gas ventilation is an integral part of partial liquid ventilation (PLV), the role of ventilation mode during PLV is not established, especially at a varying perfluorocarbon dose. In 10 surfactant-depleted rabbits, PLV was performed at a low dose (10 ml/kg) and at a functional residual capacity (FRC) dose (30 ml/kg) of perfluorodecalin in pressure-control (PC) and volume-control (VC) modes in balanced sequence. In these four PLV trials, PC mode was adjusted to be identical to VC mode with regard to tidal volume and inspiratory-to-expiratory ratio. PaO2 during PLV in PC mode was higher than in VC mode at the Low dose (159 plus minus 93 mm Hg, 115 plus minus 75 mm Hg, respectively: p = 0.005) and at the FRC dose (228 +/- 114 mm Hg, 164 +/- 104 mm Hg, respectively: p = 0.002). PaCO2 during PLV in PC mode was lower than in VC mode at the Low dose (59 +/- 18 mm Hg, 72 +/- 20 mm Hg, respectively: p = 0.005), whereas PaCO2 at the FRC dose was not different between modes. Curves of inspiratory flow appeared least deformed with PLV in PC mode at the Low dose, whereas they were saw-tooth deformed with PLV in VC mode at both doses. Actual time for inspiratory gas flow during PLV was shorter in PC mode compared with VC mode at both doses. In conclusion, in surfactant-depleted rabbit, gas exchange during PLV was better with PC mode compared with VC mode, especially at a low perfluorocarbon dose. Given the same tidal volume, PC appeared to insufflate the perfluorocarbon-filled lung better than VC at both low and FRC doses of perfluorocarbon.

摘要

尽管气体通气是部分液体通气(PLV)不可或缺的一部分,但PLV期间通气模式的作用尚未明确,尤其是在全氟碳剂量变化时。在10只表面活性剂缺乏的兔子中,以平衡顺序在压力控制(PC)和容量控制(VC)模式下,分别以低剂量(10 ml/kg)和功能残气量(FRC)剂量(30 ml/kg)的全氟萘烷进行PLV。在这四项PLV试验中,PC模式在潮气量和吸呼比方面调整为与VC模式相同。在低剂量时(分别为159±93 mmHg、115±75 mmHg:p = 0.005)和FRC剂量时(分别为228±114 mmHg、164±104 mmHg:p = 0.002),PC模式下PLV期间的PaO2高于VC模式。在低剂量时,PC模式下PLV期间的PaCO2低于VC模式(分别为59±18 mmHg、72±20 mmHg:p = 0.005),而在FRC剂量时,两种模式下的PaCO2没有差异。在低剂量时,PC模式下PLV的吸气气流曲线变形最小,而在两种剂量下,VC模式下PLV的吸气气流曲线呈锯齿状变形。在两种剂量下,PC模式下PLV期间吸气气流的实际时间均比VC模式短。总之,在表面活性剂缺乏的兔子中,与VC模式相比,PC模式下PLV期间的气体交换更好,尤其是在低全氟碳剂量时。在相同潮气量下,在低剂量和FRC剂量的全氟碳时,PC似乎比VC能更好地向充满全氟碳的肺充气。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验